MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/andr.12885

Медицинская библиотека · Andrology · 2020

Rat model and validation of a modified single-armed suture technique for microsurgical vasoepididymostomy: Guo's SA-LIVE.

Yuan Yiming, Fang Dong, Lei Hongen, Li Meng, Cheng Wanjun, Gao Bing, Peng Jing, Zhang Zhichao, Xin Zhongcheng, Guo Yinglu

СтатьяВалидационное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Double-armed suture longitudinal intussusception vasoepididymostomy (DA-LIVE) has been widely adopted owing to its simplicity and high success rate; however, specialized double-armed microsutures are required.

OBJECTIVE

To provide a novel single-armed suture longitudinal intussusception vasoepididymostomy (SA-LIVE) technique using only two single-armed sutures, named Guo's SA-LIVE.

MATERIALS AND

METHODS

Four weeks after vasectomy in male adult Wistar rats, vasoepididymostomies were performed using DA-LIVE, SA-LIVE, or Guo's SA-LIVE. After 12 weeks, functional patency was functionally assessed by evaluating for motile spermatozoa distal to the anastomosis. If no motile spermatozoa were visible, the mechanical patency of the anastomosis was tested by the ability of methylene blue to pass through the surgical anastomosis. The key procedure in Guo's SA-LIVE was cutting each needle with over 1cm attaching suture and making a flat overhand bend knot to tie the needle to the other end of the suture, after the needles were passed through the epididymal tubule and then the vasal lumen in an inside-out fashion, and then, the needles were passed through the vasal lumen in an inside-out fashion.

RESULTS

The proportions of functional patency were 50.0% (3/6), 33.3% (2/6), and 50% (3/6) for the DA-LIVE, SA-LIVE, and Guo's SA-LIVE groups, respectively (P = .799). The proportions of mechanical plus functional patency for the three methods were 83.3% (5/6), 66.7% (4/6), and 83.3% (5/6), respectively (P = .725). The mean anastomosis times for the three LIVE techniques and the proportions of complications were similar (P = .150 and .758, respectively).

CONCLUSIONS

Guo's single-armed suture technique is a potentially effective alternative to perform vasoepididymostomy when specialized double-armed microsutures are not available based on the current animal experiment.

Для цитирования: Yuan Yiming, Fang Dong, Lei Hongen, Li Meng, Cheng Wanjun, Gao Bing, Peng Jing, Zhang Zhichao, Xin Zhongcheng, Guo Yinglu. Rat model and validation of a modified single-armed suture technique for microsurgical vasoepididymostomy: Guo's SA-LIVE.. Andrology. 2020. DOI: 10.1111/andr.12885.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.