Animal models and experimental medicine · 2022
Histological and magnetic resonance imaging assessment of Liqoseal in a spinal in vivo pig model.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Slot Emma M H, Bergmann Wilhelmina, Kinaci Ahmet, de Boer Bart, Moayeri Nizar, Redegeld Saskia, van Thoor Sander, van Doormaal Tristan P C
Аннотация
BACKGROUND: Liqoseal (Polyganics, B.V.) is a dural sealant patch for preventing postoperative cerebrospinal fluid (CSF) leakage. It has been extensively tested preclinically and CE (Conformité Européenne) approved for human use after a first cranial in-human study. However, the safety of Liqoseal for spinal application is still unknown. The aim of this study was to assess the safety of spinal Liqoseal application compared with cranial application using histology and magnetic resonance imaging characteristics.
METHODS: Eight female Dutch Landrace pigs underwent laminectomy, durotomy with standard suturing and Liqoseal application. Three control animals underwent the same procedure without sealant application. The histological characteristics and imaging characteristics of animals with similar survival times were compared to data from a previous cranial porcine model.
RESULTS: Similar foreign body reactions were observed in spinal and cranial dura. The foreign body reaction consisted of neutrophils and reactive fibroblasts in the first 3 days, changing to a chronic granulomatous inflammatory reaction with an increasing number of macrophages and lymphocytes and the formation of a fibroblast layer on the dura by day 7. Mean Liqoseal plus dura thickness reached a maximum of 1.2 mm (range 0.7-2.0 mm) at day 7.
CONCLUSION: The spinal dural histological reaction to Liqoseal during the first 7 days was similar to the cranial dural reaction. Liqoseal did not swell significantly in both application areas over time. Given the current lack of a safe and effective dural sealant for spinal application, we propose that an in-human safety study of Liqoseal is the logical next step.
METHODS: Eight female Dutch Landrace pigs underwent laminectomy, durotomy with standard suturing and Liqoseal application. Three control animals underwent the same procedure without sealant application. The histological characteristics and imaging characteristics of animals with similar survival times were compared to data from a previous cranial porcine model.
RESULTS: Similar foreign body reactions were observed in spinal and cranial dura. The foreign body reaction consisted of neutrophils and reactive fibroblasts in the first 3 days, changing to a chronic granulomatous inflammatory reaction with an increasing number of macrophages and lymphocytes and the formation of a fibroblast layer on the dura by day 7. Mean Liqoseal plus dura thickness reached a maximum of 1.2 mm (range 0.7-2.0 mm) at day 7.
CONCLUSION: The spinal dural histological reaction to Liqoseal during the first 7 days was similar to the cranial dural reaction. Liqoseal did not swell significantly in both application areas over time. Given the current lack of a safe and effective dural sealant for spinal application, we propose that an in-human safety study of Liqoseal is the logical next step.