MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ab.2007.08.030

Медицинская библиотека · Analytical biochemistry · 2007

Refinement of a radioreceptor binding assay for nicotinic acid adenine dinucleotide phosphate.

Lewis Alexander M, Masgrau Roser, Vasudevan Sridhar R, Yamasaki Michiko, O'Neill John S, Garnham Clive, James Kristin, Macdonald Andrew, Ziegler Mathias, Galione Antony, Churchill Grant C

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

The measurement of changes in nicotinic acid adenine dinucleotide phosphate (NAADP) levels in cells has been, and remains, key to the investigation of the functions of NAADP as a Ca2+ -releasing second messenger. Here we provide details of how to isolate NAADP from cells by extraction with perchloric acid and then measure the NAADP using a radioreceptor assay. We demonstrate that NAADP is neither generated nor broken down during sample processing conditions and that radioreceptor assay is highly selective for the detection of NAADP under cell extract conditions. Furthermore, a number of improvements, such as solid-state detection of the radioactivity, are incorporated to enhance the safety of the procedure. Finally, we have developed a new method to prevent the endogenous metabolism of NAADP by chelating Ca2+ with bis-(o-aminophenoxy)ethane-N,N,N',N'-tetraacetic acid (BAPTA), thereby reducing the difficulty of catching a small transient rise in NAADP levels. In summary, we have refined and improved a method for measuring NAADP levels and presented it in a manner accessible to a wide range of laboratories. It is expected that this will enhance research in the NAADP field.

Для цитирования: Lewis Alexander M, Masgrau Roser, Vasudevan Sridhar R, Yamasaki Michiko, O'Neill John S, Garnham Clive, James Kristin, Macdonald Andrew, Ziegler Mathias, Galione Antony, Churchill Grant C. Refinement of a radioreceptor binding assay for nicotinic acid adenine dinucleotide phosphate.. Analytical biochemistry. 2007. DOI: 10.1016/j.ab.2007.08.030.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.