An in vitro study to compare 99mTc-stannous colloids and 99mTc-HMPAO for labelling human leukocytes.

Capriotti G, D'Alessandria C, Garin E, Weber E, Devillers A, Lehmann K, Corsetti F, Lecloirec J, Meller J, Becker W, Moisan A, Signore A

Сравнительное исследованиеОценочное исследованиеСтатьяПеревод в очереди

Аннотация

AIM: Aim of the present study was to compare in vitro the labelling efficiency (LE) and cell viability (TBE) of autologous leukocytes labelled with (99m)Tc-SnF(2) and (99m)Tc-HMPAO, and to evaluate the quantity and quality of spontaneously released (99m)Tc (SR) from labelled cells at several time points after labelling.

METHODS

A total of 14 patients with different diseases and 18 normal subjects were included in this study. A blood sample was collected from each patient; purified autologous leukocytes were divided into 2 samples and labelled with (99m)Tc-SnF(2) and (99m)Tc-HMPAO. LE was evaluated at the end of labelling and TBE and SR were evaluated at 10 min and 1 h, 2 h and 4 h after labelling.

RESULTS

LE of (99m)Tc-SnF(2)-WBC was higher than (99m)Tc-HMPAO-WBC (61.2+/-18.7% and 43.3+/-11.3; p<0.0001) and we found an inverse correlation between blood glucose and labelling efficiency for both methods (p=0.02). Minimal differences were also observed between 2 methods after 10 min and 1 h, as far as the cell viability is concerned. The percentage of radioactivity spontaneously released from (99m)Tc-SnF(2)-WBC was significantly higher compared to (99m)Tc-HMPAO-WBC at each time point. Radioactivity released from labelled cells was predominantly (99m)Tc-SnF(2) and (99m)Tc-HMPAO with few free (99m)Tc (<20%).

CONCLUSION

Both radiopharmaceuticals are not toxic for WBC. Labelling with (99m)Tc-SnF(2) give a higher LE than with (99m)Tc-HMPAO; however, radiolabelled colloids are more released from labelled cells over a period of 4 h. While (99m)Tc-HMPAO is physiological excreted into gastrointestinal tract, (99m)Tc-SnF(2) can be re-uptaken in vivo by reticulo-endothelial cells of liver and spleen. These findings suggest that (99m)Tc-SnF(2)-WBC might be better than (99m)Tc-HMPAO-WBC for studying inflammatory bowel diseases.

Для цитирования: Capriotti G, D'Alessandria C, Garin E, Weber E, Devillers A, Lehmann K, Corsetti F, Lecloirec J, Meller J, Becker W, Moisan A, Signore A. An in vitro study to compare 99mTc-stannous colloids and 99mTc-HMPAO for labelling human leukocytes.. The quarterly journal of nuclear medicine and molecular imaging : official publication of the Italian Association of Nuclear Medicine (AIMN) [and] the International Association of Radiopharmacology (IAR), [and] Section of the Society of.... 2004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.