MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1259/dmfr.20150332

Медицинская библиотека · Dento maxillo facial radiology · 2015

Comparison of different methods to assess alveolar cleft defects in cone beam CT images.

de Rezende Barbosa Gabriella Lopes, Wood Jeyhan S, Pimenta Luiz A, Maria de Almeida Solange, Tyndall Donald A

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

This study aimed to evaluate the accuracy of three different methods for assessing the volume of cleft defects in CBCT images. The influence of field of view (FOV) and voxel sizes was also assessed.

METHODS

Using three radio-opaque plastic skulls, unilateral defects were created to mimic alveolar clefts and were filled with wax following the contralateral side contours. They were scanned in a CBCT unit using four different acquisition protocols, varying FOV and voxel sizes. Using three different methods, the defect/wax volume was evaluated on the images by defining: (1) the width, height and facial-palatal length of the defect in maximum intensity projection; (2) the areas of the defect on axial slices; and (3) the threshold and segmentation of the region of interest. The values obtained from each method using different acquisition protocols were compared with the real volume of the wax (gold standard) using ANOVA and Tukey's test.

RESULTS

Methods 2 and 3 did not differ from the gold standard (p > 0.05). Conversely, Method 1 presented statistically significant overestimated values (p < 0.01). No differences were found among the different FOV and voxel sizes (p > 0.05).

CONCLUSIONS

CBCT volumes proved reliable for the volumetric assessment of alveolar cleft defects, when using Methods 2 and 3 regardless of FOV and voxel sizes. It may be possible to improve surgical planning and outcomes by knowing the exact volume of grafting material needed prior to the surgical intervention.

Для цитирования: de Rezende Barbosa Gabriella Lopes, Wood Jeyhan S, Pimenta Luiz A, Maria de Almeida Solange, Tyndall Donald A. Comparison of different methods to assess alveolar cleft defects in cone beam CT images.. Dento maxillo facial radiology. 2015. DOI: 10.1259/dmfr.20150332.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.