MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/mrm.1910390609

Медицинская библиотека · Magnetic resonance in medicine · 1998

Temporal and anatomical variations of brain water apparent diffusion coefficient in perinatal cerebral hypoxic-ischemic injury: relationships to cerebral energy metabolism.

Thornton J S, Ordidge R J, Penrice J, Cady E B, Amess P N, Punwani S, Clemence M, Wyatt J S

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Cerebral apparent diffusion coefficients (ADCs) were determined in nine newborn piglets before and for 48 h after transient hypoxia-ischemia. Phosphorus MRS revealed severely reduced cerebral energy metabolism during the insult and an apparently complete recovery 2 h after resuscitation commenced. At this time, mean ADC over the imaging slice (ADCglobal) was 0.88 (0.04) x 10(-9) m2 x s(-1) (mean (SD)), which was close to the baseline value of 0.92 (0.4) x 10(-9) m2 x s(-1). In seven of the animals, a "secondary" failure of energy metabolism then evolved, accompanied by a decline in ADCglobal to 0.64 (0.17) x 10(-9) m2 x s(-1) at 46 h postresuscitation (P < 0.001 versus baseline). For these seven animals, ADCglobal correlated linearly with the concentration ratio [phosphocreatine (PCr)]/[inorganic phosphate (Pi)] (0.94 < r < 0.99; P < 0.001). A nonlinear relationship was demonstrated between ADCglobal and the concentration ratio [nucleotide triphosphate (NTP)]/[Pi + PCr + 3 NTP]. The ADC reduction commenced in the parasagittal cortex before spreading in a characteristic pattern throughout the brain. ADC seems to be closely related to cerebral energy status and shows considerable potential for the assessment of hypoxic-ischemic injury in the newborn brain.

Для цитирования: Thornton J S, Ordidge R J, Penrice J, Cady E B, Amess P N, Punwani S, Clemence M, Wyatt J S. Temporal and anatomical variations of brain water apparent diffusion coefficient in perinatal cerebral hypoxic-ischemic injury: relationships to cerebral energy metabolism.. Magnetic resonance in medicine. 1998. DOI: 10.1002/mrm.1910390609.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.