MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/dss.0000000000004074

Медицинская библиотека · Dermatologic surgery : official publication for American Society for Dermatologic Surgery [et al.] · 2024

Evaluation of Physical Properties of Coated Polydioxanone Threads.

Park EunJi, Jang Tae Su, Kim Jae Kyung

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Using a thread for wound closure promotes healing and minimizes contamination by foreign substances. Threads have also been employed in esthetic surgery; however, functional threads that can improve wrinkles and rejuvenate the skin are required.

OBJECTIVE

To evaluate the suitability of polydioxanone threads coated with polyethylene glycol, hyaluronic acid, and amino acids for use in the medical field because such formulations are expected to promote regeneration and collagen synthesis.

MATERIALS AND

METHODS

Physical properties (diameter [ n = 20], tensile strength [ n = 20], strength retention rate [ n = 10], and scanning electron microscopy images) and cytotoxicity (3-[4,5-dimethylthiazol-2-yl]-2,5-diphenyltetrazolium bromide and lactate dehydrogenase assays) of polydioxanone threads coated with polyethylene glycol, hyaluronic acid, and amino acids were assessed and compared with those of uncoated polydioxanone threads. Analyses were performed using IBM SPSS Statistics (Statistical significance; p values <.05).

RESULTS

The size standards for tensile strength (≥63.5 N) and diameter (average 0.570-0.610 mm) were met. There were no differences in the physical properties of the coated and uncoated threads; however, the biocompatibility of coated threads was high owing to low cytotoxicity.

CONCLUSION

Threads coated with materials that can promote regeneration are suitable for use in the medical field.

Для цитирования: Park EunJi, Jang Tae Su, Kim Jae Kyung. Evaluation of Physical Properties of Coated Polydioxanone Threads.. Dermatologic surgery : official publication for American Society for Dermatologic Surgery [et al.]. 2024. DOI: 10.1097/dss.0000000000004074.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.