MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mat.0000000000001281

Медицинская библиотека · ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2021

Endothelial Dysfunction-related Neurological Bleeds with Continuous Flow-Left Ventricular Assist Devices Measured by Digital Thermal Monitor.

Ali Areeba, Uribe Cesar, Araujo-Gutierrez Raquel, Cruz-Solbes Ana S, Marcos-Abdala Hernan G, Youker Keith A, Guha Ashrith, Torre-Amione Guillermo, Nguyen Duc T, Graviss Edward A, Cooke John P, Bhimaraj Arvind

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Endothelial dysfunction has been demonstrated in patients with Continuous Flow-Left Ventricular Assist Devices (CF-LVADs) but association with adverse events has not been shown. We used a noninvasive, operator-independent device called VENDYS® to assess vasodilatory function based on digital thermal measurements postrelease of a brachial artery occlusion in ambulatory patients with CF-LVAD (n = 56). Aortic valve opening and pulse perception were also documented before the test. Median duration of CF-LVAD support was 438 days. The VENDYS® test generates a vascular reactivity index (VRI). Outcomes for the CF-LVAD patients were compared between VRI < 1 and VRI ≥ 1. The bleeding events were driven primarily by a difference in neurologic bleeds. Multivariate analysis showed that VRI < 1 correlated with future bleeding events (HR: 5.56; P = 0.01). The C-statistic with the VRI dichotomized as above was 0.82. There was a trend toward a worse survival in patients with poor endothelial function. Endothelial vasodilatory dysfunction measured by a simple test utilizing digital thermal monitoring can predict adverse bleeding events in patients with CF-LVADs.

Для цитирования: Ali Areeba, Uribe Cesar, Araujo-Gutierrez Raquel, Cruz-Solbes Ana S, Marcos-Abdala Hernan G, Youker Keith A, Guha Ashrith, Torre-Amione Guillermo, Nguyen Duc T, Graviss Edward A, Cooke John P, Bhimaraj Arvind. Endothelial Dysfunction-related Neurological Bleeds with Continuous Flow-Left Ventricular Assist Devices Measured by Digital Thermal Monitor.. ASAIO journal (American Society for Artificial Internal Organs : 1992). 2021. DOI: 10.1097/mat.0000000000001281.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.