MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/trstmh/trx067

Медицинская библиотека · Transactions of the Royal Society of Tropical Medicine and Hygiene · 2017

Poor performance of two rapid immunochromatographic assays for anti-Japanese encephalitis virus immunoglobulin M detection in cerebrospinal fluid and serum from patients with suspected Japanese encephalitis virus infection in Laos.

Sengvilaipaseuth Onanong, Castonguay-Vanier Josée, Chanthongthip Anisone, Phonemixay Ooyanong, Thongpaseuth Soulignasack, Vongsouvath Manivanh, Newton Paul N, Bharucha Tehmina, Dubot-Pérès Audrey

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Japanese encephalitis virus (JEV) is a leading identified cause of encephalitis in Asia, often occurring in rural areas with poor access to laboratory diagnostics. We evaluated two rapid diagnostic tests (RDTs) for anti-JEV immunoglobulin M (IgM) detection.

METHODS

Consecutive cerebrospinal fluid and serum from 388 patients (704 samples) with suspected JEV infections admitted to six hospitals in Laos were tested with one of two SD-Bioline anti-JEV IgM RDTs and the World Health Organization standard anti-JEV IgM enzyme-linked immunosorbent assay (ELISA; Panbio Japanese Encephalitis-Dengue IgM Combo ELISA.

RESULTS AND

CONCLUSIONS

The performance of both RDTs showed strikingly low sensitivity in comparison to anti-JEV IgM antibody capture ELISA (2.1-51.4%), suggesting low sensitivity of the RDTs. We highlight the fundamental prerequisite to validate RDTs prior to use to ensure that they meet standards for testing.

Для цитирования: Sengvilaipaseuth Onanong, Castonguay-Vanier Josée, Chanthongthip Anisone, Phonemixay Ooyanong, Thongpaseuth Soulignasack, Vongsouvath Manivanh, Newton Paul N, Bharucha Tehmina, Dubot-Pérès Audrey. Poor performance of two rapid immunochromatographic assays for anti-Japanese encephalitis virus immunoglobulin M detection in cerebrospinal fluid and serum from patients with suspected Japanese encephalitis virus infection in Laos.. Transactions of the Royal Society of Tropical Medicine and Hygiene. 2017. DOI: 10.1093/trstmh/trx067.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.