MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Pediatrics · 1991

Spatially localized magnetic resonance spectroscopy of the brains of normal and asphyxiated newborns.

Moorcraft J, Bolas N M, Ives N K, Sutton P, Blackledge M J, Rajagopalan B, Hope P L, Radda G K

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Phase-modulated rotating frame imaging is a modification of magnetic resonance spectroscopy, which uses a linear radiofrequency field gradient to obtain spatially localized biochemical information. Phase-modulated rotating frame imaging was used to study regional cerebral energy metabolism in the brains of 9 normal newborns and 25 newborns after birth asphyxia. Relative concentrations of phosphorus-containing metabolites and intracellular pH were determined for brain tissue at three specified depths below the brain surface for all neonates. Wide variations in metabolite ratios were seen among normal neonates, and considerable metabolic heterogeneity was demonstrated in individual neonates by depth-resolved spectroscopy. Asphyxiated neonates with severe hypoxic-ischemic encephalopathy and a poor neurodevelopmental outcome showed the expected rise in inorganic orthophosphate and fall in phosphocreatine concentrations in both global and spatially localized spectra. Phase-modulated rotating frame imaging showed that metabolic derangement was less in superficial than in deeper brain tissue. The inorganic orthophosphate-adenosine triphosphate ratio from 1 to 2 cm below the brain surface was more accurate than any global metabolite ratio for the identification of neonates with a poor short-term outcome. These data are consistent with the known vulnerability of subcortical brain tissue to hypoxic-ischemic injury in the full-term neonate.

Для цитирования: Moorcraft J, Bolas N M, Ives N K, Sutton P, Blackledge M J, Rajagopalan B, Hope P L, Radda G K. Spatially localized magnetic resonance spectroscopy of the brains of normal and asphyxiated newborns.. Pediatrics. 1991.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.