MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/chem.201103135

Медицинская библиотека · Chemistry (Weinheim an der Bergstrasse, Germany) · 2012

Multi-use NBD-based tetra-amino macrocycle: fluorescent probe for metals and anions and live cell marker.

Amatori Stefano, Ambrosi Gianluca, Fanelli Mirco, Formica Mauro, Fusi Vieri, Giorgi Luca, Macedi Eleonora, Micheloni Mauro, Paoli Paola, Pontellini Roberto, Rossi Patrizia, Varrese Maria Antonietta

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Ligand L (4-(7-nitrobenzo[1,2,5]oxadiazole-4-yl)-1,7-dimethyl-1,4,7,10-tetra-azacyclododecane) is a versatile fluorescent sensor useful for Cu(II), Zn(II) and Cd(II) metal detection, as a building block of fluorescent metallo-receptor for halide detection, and as an organelle marker inside live cells. Ligand L undergoes a chelation-enhanced fluorescence (CHEF) effect upon metal coordination in acetonitrile solution. In all three complexes investigated the metal cation is coordinatively unsaturated; thus, it can bind secondary ligands as anionic species. The crystal structure of [ZnLCl](ClO(4)) is discussed. Cu(II) and Zn(II) complexes are quenched upon halide interaction, whereas the [CdL](2+) species behaves as an OFF-ON sensor for halide anions in acetonitrile solution. The mechanism of the fluorescence response in the presence of the anion depends on the nature of the metal ion employed and has been studied by spectroscopic methods, such as NMR spectroscopy, UV/Vis and fluorescence techniques and by computational methods. Subcellular localization experiments performed on HeLa cells show that L mainly localizes in spot-like structures in a polarized portion of the cytosol that is occupied by the Golgi apparatus to give a green fluorescence signal.

Для цитирования: Amatori Stefano, Ambrosi Gianluca, Fanelli Mirco, Formica Mauro, Fusi Vieri, Giorgi Luca, Macedi Eleonora, Micheloni Mauro, Paoli Paola, Pontellini Roberto, Rossi Patrizia, Varrese Maria Antonietta. Multi-use NBD-based tetra-amino macrocycle: fluorescent probe for metals and anions and live cell marker.. Chemistry (Weinheim an der Bergstrasse, Germany). 2012. DOI: 10.1002/chem.201103135.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.