MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Zhonghua er ke za zhi = Chinese journal of pediatrics · 2003

[Transcatheter closure of atrial septal defects in 40 pediatric patients].

Deng Dong-an, Zhu Xian-yang, Hou Chuan-ju, Han Xiu-min, Wang Qi-guang, Jin Yan, Quan Wei, Liu Yang, Wang Shu-fan

Клиническое исследованиеАннотация на английскомСтатьяПеревод в очереди

Аннотация

OBJECTIVE

To evaluate the clinical efficiency of transcatheter closure of atrial septal defect (ASD) with AGA-Amplatzer occlusion device in pediatric patients.

METHODS

Forty patients with ASD, 16 males, 24 females, at a mean age of 10.2 years (ranged from 3 to 15 years of age) and with a mean weight of 35.8 kg (ranged from 11 to 87 kg) were studied. Six cases were complicated with pulmonary stenosis (PS), 1 was complicated with ventricular tachycardia (VT). Right heart catheterizations were done in 40 patients for measuring the pressures of right ventricle and pulmonary artery. The balloon diameter of ASD was measured using balloon catheter with guiding wire. The diameter of ASD was measured by TTE and/or TEE, ascertaining the location and size of ASD. Amplatzer occlusion device was sized to be equal to or 1 - 2 mm more than the diameter of balloon stretched.

RESULTS

All patients had successful implantation of the Amplatzer device. The success rate was 100%. The diameter measured by TTE was 7 - 30 mm (mean 17.12 mm). The diameter measured by TEE was 7 - 32 mm (mean 18.44 mm). The diameter of balloon stretched of ASD was 8 - 34 mm. Of the 40 cases, 6 were complicated with PS and accepted percutaneous balloon valvuloplasty (PBPV). One case was complicated with VT and accepted radiofrequency catheter ablation (RFCA). Neither complication nor residual shunt was found in any of the patients. The patients were recovered and followed up for 3 or 4 days after deployment of the Amplatzer device. Clinical symptom, cardiac murmur, and findings in ECG, echocardiography and X-ray were improved markedly.

CONCLUSION

AGA-Amplatzer occlusion device is safe and efficient in pediatric patients with ASD.

Для цитирования: Deng Dong-an, Zhu Xian-yang, Hou Chuan-ju, Han Xiu-min, Wang Qi-guang, Jin Yan, Quan Wei, Liu Yang, Wang Shu-fan. [Transcatheter closure of atrial septal defects in 40 pediatric patients].. Zhonghua er ke za zhi = Chinese journal of pediatrics. 2003.