MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/lary.27528

Медицинская библиотека · The Laryngoscope · 2018

When to replace legacy cochlear implants for technological upgrades: Indications and outcomes.

Holcomb Meredith A, Burton Jane A, Dornhoffer James R, Camposeo Elizabeth L, Meyer Ted A, McRackan Theodore R

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To determine indications, surgical efficacy, and audiologic outcomes of replacing Advanced Bionics Clarion C1.2 internal devices (Advanced Bionics, LLC, Valencia, CA) as a means of technology upgrade.

STUDY

DESIGN

Retrospective review, case series.

METHODS

Ten patients were initially implanted as a child (mean age = 3.87 years) and underwent cochlear implant reimplantation (CIR) with current Advanced Bionics internal device as a young adult (mean duration of implant use = 15.66 years). Demographic data and pre- and post-CIR speech perception scores were collected.

RESULTS

Technology upgrade was the primary (9) or secondary (1) motivation for CIR. No surgical complications were noted, and full insertion was obtained in nine cases. Intraoperative impedance levels and neural response imaging measures were within normal limits for eight patients. At most recent post-CIR follow-up evaluation, all patients (100%) performed within or better than the 95% confidence interval of their pre-CIR word and sentence recognition scores; and 55.6%, 50.0%, and 50.0% of patients performed above the 95% confidence interval of their pre-CIR scores for the CNC words, sentences in quiet, and sentences in noise, respectively.

CONCLUSION

Post-CIR audiological benefit was stable or improved compared to pre-CIR results in all categories by 3 months after reactivation. Given these results, patients who are unable to use the most current external processors due to incompatibility with a legacy internal device could consider reimplanation to optimize their overall performance with a cochlear implant.

LEVEL OF EVIDENCE: 4 Laryngoscope, 129:748-753, 2019.

Для цитирования: Holcomb Meredith A, Burton Jane A, Dornhoffer James R, Camposeo Elizabeth L, Meyer Ted A, McRackan Theodore R. When to replace legacy cochlear implants for technological upgrades: Indications and outcomes.. The Laryngoscope. 2018. DOI: 10.1002/lary.27528.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.