MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/echo.13408

Медицинская библиотека · Echocardiography (Mount Kisco, N.Y.) · 2016

Quantitative echocardiographic measures in the assessment of single ventricle function post-Fontan: Incorporation into routine clinical practice.

Rios Rodrigo, Ginde Salil, Saudek David, Loomba Rohit S, Stelter Jessica, Frommelt Peter

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Quantitative echocardiographic measurements of single ventricular (SV) function have not been incorporated into routine clinical practice.

METHODS

A clinical protocol, which included quantitative measurements of SV deformation (global circumferential and longitudinal strain and strain rate), standard deviation of time to peak systolic strain, myocardial performance index (MPI), dP/dT from an atrioventricular valve regurgitant jet, and superior mesenteric artery resistance index, was instituted for all patients with a history of Fontan procedure undergoing echocardiography. All measures were performed real time during clinically indicated studies and were included in clinical reports.

RESULTS

A total of 100 consecutive patients (mean age = 11.95±6.8 years, range 17 months-31.3 years) completed the protocol between September 1, 2014 to April 29, 2015. Deformation measures were completed in 100% of the studies, MPI in 93%, dP/dT in 55%, and superior mesenteric artery Doppler in 82%. The studies were reviewed to assess for efficiency in completing the protocol. The average time for image acquisition was 27.4±8.8 (range 10-62 minutes). The average time to perform deformation measures was 10.8±5.5 minutes (range 5-35 minutes) and time from beginning of imaging to report completion was 53.4±13.7 minutes (range 27-107 minutes). There was excellent inter-observer reliability when deformation indices were blindly repeated. Patients with a single left ventricle had significantly higher circumferential strain and strain rate, longitudinal strain and strain rate, and dP/dT compared to a single right ventricle. There were no differences in quantitative indices of ventricular function between patients <10 vs. >10 years post-Fontan.

CONCLUSION

Advanced quantitative assessment of SV function post-Fontan can be consistently and efficiently performed real time during clinically indicated echocardiograms with excellent reliability.

Для цитирования: Rios Rodrigo, Ginde Salil, Saudek David, Loomba Rohit S, Stelter Jessica, Frommelt Peter. Quantitative echocardiographic measures in the assessment of single ventricle function post-Fontan: Incorporation into routine clinical practice.. Echocardiography (Mount Kisco, N.Y.). 2016. DOI: 10.1111/echo.13408.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.