MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.wneu.2020.02.002

Медицинская библиотека · World neurosurgery · 2020

The Application of Resting Magnetic Resonance Imaging in the Cognitive Judgment of Parkinson.

Mu Lin, Zhou Qiang, Sun Dawei, Wang Min, Chai Xin, Wang Meng

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

In this study, we considered the treatment of cognitive characteristics of Parkinson's subtypes under resting magnetic resonance imaging scans, and used magnetic resonance imaging to analyze brain activity characteristics of patients with Parkinson's subtypes at rest.

METHODS

In this study, patients with neurological Parkinson's disease subtypes were selected: 27 patients in the tremor group, 33 patients in the orthostatic gastric instability group, and 3 patients with mild cognitive impairment and neuropathic Parkinson's disease. Scientific treatment was adopted.

RESULTS

Nineteen patients had mild cognitive dysfunction tremor and unstable posture, and 23 of them had mild cognitive dysfunction. Fifteen healthy controls were subjected to resting state functional magnetic resonance imaging by plane echo imaging sequence scanning. Neurological diseases-Regional consistency analysis of brain regions in patients with Parkinson's disease increased, including the right lower lobe, while regional consistency analysis of brain regions decreased, including the right frontal gyrus, right middle anterior gyrus, and lateral cerebellum.

CONCLUSIONS

The experimental results show that the local consistency analysis method based on resting magnetic resonance imaging scan can effectively detect the differences in early neural activity in patients with Parkinson's disease subtype cognitive impairment, and can effectively reflect the brain characteristics of Parkinson's disease.

Для цитирования: Mu Lin, Zhou Qiang, Sun Dawei, Wang Min, Chai Xin, Wang Meng. The Application of Resting Magnetic Resonance Imaging in the Cognitive Judgment of Parkinson.. World neurosurgery. 2020. DOI: 10.1016/j.wneu.2020.02.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.