BACKGROUND

Regadenoson is a selective adenosine receptor agonist. It is currently unclear if the level of hyperemia differs between stress agents. We compared Myocardial Blood Flow (MBF) and Myocardial Flow Reserve (MFR) response on CZT-SPECT Myocardial Perfusion Imaging (MPI) to evaluate if dipyridamole and regadenoson could induce the same level of hyperemia.

METHODS

228 patients with dynamic CZT-SPECT MPI were retrospectively analyzed (66 patients stressed with regadenoson and 162 with dipyridamole) in terms of MBF and MFR. To rule out confounding factors, two groups of 41 patients were matched for clinical characteristics in a sub-analysis, excluding high cardiovascular risk patients.

RESULTS

Overall stress MBF was higher in regadenoson patients (1.71 ± 0.73 vs. 1.44 ± 0.55 mL·min-1·g-1 for regadenoson and dipyridamole, respectively, p < .05). However, when confounding factors were ruled out, stress MBF (1.57 ± 0.56 vs. 1.61 ± 0.62 mL·min-1·g-1 for dipyridamole and regadenoson, respectively, p = .88) and MFR (2.62 ± 0.77 vs. 2.46 ± 0.76 for dipyridamole and regadenoson, respectively, p = .40) were not different between regadenoson and dipyridamole.

CONCLUSIONS

Our results suggest that dipyridamole and regadenoson induce equivalent hyperemia in dynamic SPECT with similar stress MBF and MFR in comparable patients.

Для цитирования: Brana Quentin, Thibault Frédérique, Courtehoux Maxime, Metrard Gilles, Ribeiro Maria Joao, Angoulvant Denis, Bailly Matthieu. Regadenoson versus dipyridamole: Evaluation of stress myocardial blood flow response on a CZT-SPECT camera.. Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology. 2020. DOI: 10.1007/s12350-020-02271-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.