MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/heart.88.5.510

Медицинская библиотека · Heart (British Cardiac Society) · 2002

Influence of the pulmonary annulus diameter on pulmonary regurgitation and right ventricular pressure load after repair of tetralogy of Fallot.

Uebing A, Fischer G, Bethge M, Scheewe J, Schmiel F, Stieh J, Brossmann J, Kramer H H

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To assess the influence of the pulmonary annulus diameter after reconstruction of the right ventricular (RV) outflow tract at repair of tetralogy of Fallot on pulmonary regurgitation and RV pressure load; and to evaluate the impact of pulmonary regurgitation on RV size and function.

SETTING

Paediatric cardiology and diagnostic radiology departments of a tertiary referral centre.

PATIENTS: 67 patients were examined at a median of 4.8 years after repair of tetralogy of Fallot by means of biplane angiocardiography and magnetic resonance imaging (MRI).

MAIN OUTCOME MEASURES: Pulmonary annulus diameter and area, pulmonary regurgitant fraction, RV to left ventricular (LV) systolic pressure ratio, RV end diastolic volume, and RV ejection fraction were assessed.

RESULTS

There was a significant positive correlation between pulmonary annulus area indexed to body surface area and pulmonary regurgitation (angiocardiography: r = 0.55, p < 0.001; MRI: r = 0.59, p < 0.001). No significant correlation was found between pulmonary annulus index and RV to LV systolic pressure ratio even in patients with small pulmonary annulus areas (r = -0.24, NS). Pulmonary regurgitant fraction was positively correlated with normalised RV end diastolic volume (angiocardiography: r = 0.42, p < 0.05; MRI: r = 0.56, p < 0.01). RV ejection fraction decreased with increasing pulmonary regurgitation (angiocardiography: r = -0.42, p < 0.05; MRI: r = -0.41, p < 0.05).

CONCLUSIONS

The extent of pulmonary regurgitation after tetralogy of Fallot repair correlates with the postoperative size of the pulmonary annulus and is closely correlated with the enlargement of the RV. An enlargement of the pulmonary annulus to the second lower standard deviation of normal results in a decrease of pulmonary regurgitation and is sufficient to achieve adequate RV pressure unloading.

Для цитирования: Uebing A, Fischer G, Bethge M, Scheewe J, Schmiel F, Stieh J, Brossmann J, Kramer H H. Influence of the pulmonary annulus diameter on pulmonary regurgitation and right ventricular pressure load after repair of tetralogy of Fallot.. Heart (British Cardiac Society). 2002. DOI: 10.1136/heart.88.5.510.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.