Zero mortality of continuous veno-venous hemodiafiltration with PMMA hemofilter after pediatric cardiac surgery.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Miyamoto Takashi, Yoshimoto Akihiro, Tatsu Kazuhito, Ikeda Kentaro, Ishii Yoichiro, Kobayashi Tomio

Аннотация

OBJECTIVE: Continuous veno-venous hemodiafiltration (CVVH) is used as one of the modalities of continuous renal replacement therapy (CRRT) in pediatric intensive units. The aim of our study was to investigate the use of CVVH in small children with acute renal failure (ARF) after cardiac surgery.

PATIENT AND METHODS: Between June 2005 and June 2008, 7 patients who required dialysis after pediatric cardiac surgery without ECMO underwent CVVH with polymethylmethacrylate membrane (PMMA) treatment. The definition of ARF was based on a 100% rise in serum creatinine (Cr) concentration, oliguria. On the other hand, PMMA-CVVH was weaned in patients with satisfactory urine output, stable biochemical markers of renal function and adequate fluid balance.

RESULTS: All patients treated with PMMA-CVVH alone (4 boys, 3 girls) had a median age of 36 months and a median body weight of 11 kg. The averaged established time from cardiac operation to CVVH was 2.6 days. There was a significant decrease in the post-filter compared with pre-filter levels of BUN, Cr, potassium concentration. There were no significant changes in systolic blood pressure, lactate level and CRP; however, it was unnecessary for all patients to use epinephrine.

CONCLUSIONS: Continuous veno-venous hemodiafiltration with PMMA-CVVH without ECMO achieved a surprisingly Zero mortality.