Effectiveness of Two Targeted Temperature Management Methods After Pediatric Postcardiac Arrest: A Multicenter International Study.
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Yunge Mauricio, Cordero Jaime, Martinez Daniela, Bustos Raul, Wegner Adriana, Castro Magdalena, Arrau Lorena, Diaz Betsy, Dalmazzo Roberto, Hickmann Lilian, Lapadula Michelangelo, Yañez Leticia, Roque Jorge, Cecchetti Corrado, Bravo Pablo, Cruces Pablo, Acuña Carlos, Oyaguez Pablo, Miras Alicia, Morales Antonio, Nieto Manuel, Lopez Yolanda, Morales Gonzalo, Drago Michele, Nalegach Maria Elisa, Sepulveda German, Menchaca Amanda, Jerez Florencia, Glasinovic Maritza, Mallea Fernando, Lopez-Herce Jesus
Аннотация
DESIGN: Prospective, multicenter, nonrandomized, study.
SETTING: PICUs of 20 hospitals in South America, Spain, and Italy, 2012-2014.
PATIENTS: Under 18 years old with a cardiac arrest longer than 2 minutes, in coma and surviving to PICU admission requiring mechanical ventilation were included.
METHODS: TTM to 32-34°C was performed by prospectively designed protocol across 20 centers, with either servo-controlled system or no servo-controlled system methods, depending on servo-controlled system availability. We analyzed clinical data, cardiac arrest, temperature, mechanical ventilation duration, length of hospitalization, complications, survival, and neurologic outcomes at 6 months.
PRIMARY OUTCOME: feasibility, safety and quality assurance of the cooling technique and secondary outcome: survival and Pediatric Cerebral Performance Category at 6 months.
MEASUREMENTS AND MAIN RESULTS: Seventy patients were recruited, 51 of 70 TTM (72.8%) with servo-controlled system. TTM induction, maintenance, and rewarming were feasible in both groups. Servo-controlled system was more effective than no servo-controlled system in maintaining TTM (69 vs 60%; p = 0.004). Servo-controlled system had fewer temperatures above 38.1°C during the 5 days of TTM (0.1% vs 2.9%; p < 0.001). No differences in mortality, complications, length of mechanical ventilation and of stay, or neurologic sequelae were found between the two groups.
CONCLUSIONS: TTM protocol (for cooling, maintenance and rewarming) following return of spontaneous circulation after cardiac arrest in children was feasible and safe with both servo-controlled system and no servo-controlled system techniques. Achieving, maintaining, and rewarming within protocol targets were more effective with servo-controlled system versus no servo-controlled system techniques.