Thrombosis and haemostasis · 2024
Long-Term Safety of a Four-Factor Prothrombin Complex Concentrate (Kcentra®/Beriplex® P/N): An Updated Pharmacovigilance Review.
СтатьяОбзорНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Milling Truman J, Voronov Anna, Schmidt Dirk S, Lindhoff-Last Edelgard
Аннотация
INTRODUCTION: Four-factor prothrombin complex concentrate (4F-PCC) is recommended for vitamin K antagonist reversal in patients with major bleeding or in need of surgery. The most important risk associated with the use of 4F-PCC is the occurrence of thromboembolic events (TEEs). In this review, we aim to evaluate the safety profile of a 4F-PCC (Kcentra®/Beriplex® P/N; CSL Behring, Marburg, Germany) by reviewing pharmacovigilance data.
METHODS: A retrospective analysis of postmarketing pharmacovigilance data of Kcentra®/Beriplex® P/N from February 1996 to April 2022 was performed and complemented by a review of clinical studies published between January 2012 and April 2022.
RESULTS: A total of 2,321,443 standard infusions of Kcentra®/Beriplex® P/N were administered during the evaluation period. Adverse drug reactions (ADRs) were reported in 614 cases (∼1 per 3,781 standard infusions) and 233 of these cases (37.9%) experienced suspected TEEs related to 4F-PCC (∼1 per 9,963 standard infusions); most of these cases had pre-existing or concomitant conditions likely to be significant risk factors for thrombosis. TEE rates were similar when 4F-PCC was used on-label or off-label for direct oral anticoagulant-associated bleeding. Thirty-six cases (5.9%) reported hypersensitivity type reactions (∼1 per 64,485 standard infusions). No confirmed case of viral transmission related to 4F-PCC use was reported. The published literature also revealed a favorable safety profile of 4F-PCC.
CONCLUSION: Analysis of postmarketing pharmacovigilance safety reports demonstrated that treatment with 4F-PCC was associated with few ADRs and a low rate of TEEs across multiple indications and settings, thus confirming a positive safety profile of 4F-PCC.
METHODS: A retrospective analysis of postmarketing pharmacovigilance data of Kcentra®/Beriplex® P/N from February 1996 to April 2022 was performed and complemented by a review of clinical studies published between January 2012 and April 2022.
RESULTS: A total of 2,321,443 standard infusions of Kcentra®/Beriplex® P/N were administered during the evaluation period. Adverse drug reactions (ADRs) were reported in 614 cases (∼1 per 3,781 standard infusions) and 233 of these cases (37.9%) experienced suspected TEEs related to 4F-PCC (∼1 per 9,963 standard infusions); most of these cases had pre-existing or concomitant conditions likely to be significant risk factors for thrombosis. TEE rates were similar when 4F-PCC was used on-label or off-label for direct oral anticoagulant-associated bleeding. Thirty-six cases (5.9%) reported hypersensitivity type reactions (∼1 per 64,485 standard infusions). No confirmed case of viral transmission related to 4F-PCC use was reported. The published literature also revealed a favorable safety profile of 4F-PCC.
CONCLUSION: Analysis of postmarketing pharmacovigilance safety reports demonstrated that treatment with 4F-PCC was associated with few ADRs and a low rate of TEEs across multiple indications and settings, thus confirming a positive safety profile of 4F-PCC.