m+Medelevator.RU
← Поиск публикаций
Analytica chimica acta · 2024

Rapid identification of mushroom toxins by direct electrospray probe mass spectrometry for emergency care.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Su Hung, Jiang Zong-Han, Hsu Yi-Wen, Wang Yu-Chi, Chen Yun-Yi, Wu Deng-Chyang, Shiea Jentaie, Lee Chi-Wei

Аннотация

Mushroom poisoning occurs frequently after the ingestion of toxic wild mushrooms misidentified as edible species. The goal of this study is to develop a mass spectrometric platform to bypass the need for morphological recognition of poisonous mushrooms by experts and rapidly identify the toxins in the mushrooms for emergency care. Trace mushroom toxins were collected by penetrating and removing the mushrooms surface for 3 mm with a direct electrospray probe (DEP). The analytes on the DEP were then dissolved in the solution (70% isopropanol containing 0.1% acetic acid) flowing out of a solvent reservoir on the DEP. Electrospray ionization was induced from the sample solution as a high electric field was generated between the DEP and MS inlet. The obtaining mass spectrometric results were further analyzed with principal component analysis (PCA) to classify mushroom toxins. The mass spectrometric platform for detecting mushroom toxins was assessed for its sensitivity, precision, and efficiency by determining its limit-of-detection (LOD), repeatability, and turnaround time, respectively. As a result, the LODs of the mushroom toxins in pure methanol and spiked in human vomitus by DEP/MS were within 0.001-0.5 ng/μL and 0.01-1 ng/μL, respectively. Linear responses of the mushroom toxins in pure methanol with concentrations between 0.01 and 5 ng/μL (R2 between 0.9922 and 0.998) were obtained. The repeatability of the approach (n = 10) was shown in the low relative standard deviation value (<15%) from ten repeat analysis of mushroom toxins standard solution. The corresponding toxic compounds were identified through matching of the obtained mass spectrometric data with those provided by its companion database library of mushroom toxins. Since no time-consuming pretreatment of the samples is required, identification of mushroom toxins with DEP/MS was complete within 1 min. This will be helpful for the emergency physicians to make correct clinical judgment and prescribe appropriate medical treatment in a timely manner.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты