MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/v17111442

Медицинская библиотека · Viruses · 2025

Diagnostic Performance of a Silver-Amplified vs. a Non-Amplified Lateral Flow Kit for Adenoviral Conjunctivitis: A Multicenter Prospective Study.

Fujimoto Tsuguto, Hanaoka Nozomu, Takahashi Kenichiro, Kaneko Hisatoshi, Kobayashi Masaaki, Nakagawa Hisashi, Hatano Hiroshi, Tsukahara-Kawamura Tomoko, Migita Hironori, Nakamura Kentaro, Kuramoto Kiyoharu, Uchio Eiichi

СтатьяМногоцентровое исследованиеСравнительное исследованиеПеревод в очереди

Аннотация

Accurate diagnosis of adenoviral conjunctivitis is critical for timely treatment and infection control. However, conventional lateral flow kits often lack sufficient sensitivity, especially in mild cases. This multicenter prospective study evaluated the diagnostic performance of silver-amplified lateral flow kits (SA-LFKs) compared with non-silver-amplified kits (NSA-LFKs), using real-time polymerase chain reaction (qPCR) as the reference standard. Tear samples from 200 patients with suspected adenoviral conjunctivitis were collected across four clinics and analyzed for sensitivity, specificity, and genotype coverage. The SA-LFK demonstrated significantly higher sensitivity (86.0%) than the NSA-LFK (72.0%) (p < 0.001), with both kits showing high specificity (100% and 98.1%, respectively). Pooled analysis revealed that sensitivity was significantly lower in mild-to-moderate cases than in severe cases for both kits, suggesting that clinical severity influences detection performance. Across all severity levels, the SA-LFK consistently demonstrated higher sensitivity than the NSA-LFK, including in mild-to-moderate cases (77.8% vs. 59.3%, p = 0.004), supporting its superior diagnostic performance. The SA-LFK showed robust performance across eight identified adenovirus genotypes and maintained higher positivity rates even at lower viral loads. These findings support the clinical utility of SA-LFKs for early diagnosis and outbreak containment in diverse settings.

Для цитирования: Fujimoto Tsuguto, Hanaoka Nozomu, Takahashi Kenichiro, Kaneko Hisatoshi, Kobayashi Masaaki, Nakagawa Hisashi, Hatano Hiroshi, Tsukahara-Kawamura Tomoko, Migita Hironori, Nakamura Kentaro, Kuramoto Kiyoharu, Uchio Eiichi. Diagnostic Performance of a Silver-Amplified vs. a Non-Amplified Lateral Flow Kit for Adenoviral Conjunctivitis: A Multicenter Prospective Study.. Viruses. 2025. DOI: 10.3390/v17111442.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.