[The cardiac index dynamics of patients after the radical correction of tetralogy of Fallot depending on the level of the pressure-support ventilation (PSV) regimen].
Аннотация
Seventeen patients were examined, reoperated on for correction of Fallot's tetralogy on the open heart after a previous aortopulmonary anastomosis. Pressure support ventilation (PSV) was used in all patients during transfer to spontaneous pressure, making use of different levels of pressure support (20, 15, 13, 10, and 8 mm H2O). Decrease of pressure support from 20-15 mm H2O to 13 mm H2O resulted in a sharp increase of cardiac index. We explain this phenomenon by a drastic increase of the respiratory volume during the use of high PSV levels (20-15 mm H2O), surpassing 1.5-2 times the physiological and age-specific norm; this leads to a sharp increase of the mean intrathoracic pressure, disturbing the cardiovascular function.