m+Medelevator.RU
← Поиск публикаций
The American surgeon · 2001

Effect of a composite membrane of chitosan and poloxamer gel on postoperative adhesive interactions.

Оценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Vlahos A, Yu P, Lucas C E, Ledgerwood A M

Аннотация

Excessive postoperative adhesion formation is a major result of surgery. The adhesion reduction effects of a chitosan membrane and poloxamer gel barrier were measured in a rat peritoneal model. Forty-four male Sprague-Dawley rats were divided into four groups (control, poloxamer, chitosan, and poloxamer+chitosan sandwich). Two cm2 of cecal serosa and the adjacent abdominal wall were abraded. The denuded cecum was covered with either a chitosan membrane, a poloxamer gel, chitosan in a sandwich configuration with poloxamer on both sides, or neither (control group) and apposed to the abdominal wall. Fourteen days after surgery adhesions were graded using a whole-number scoring system of zero to five. Adhesion strength was determined using a whole-number system of one to four. Adhesion area was measured on a continuous scale of adhesion severity. Adhesion grades were highest in the control group (5.00 +/- 0.00) and were significantly (P < 0.05) lower in the poloxamer group (3.50 +/- 1.35), the chitosan group (1.64 +/- 1.63), and the poloxamer+chitosan group (1.18 +/- 1.25). The two chitosan-containing groups also had significantly (P < 0.05) reduced adhesion grades in comparison with the poloxamer group. Adhesion area in both chitosan-containing groups was reduced in comparison with control and adhesion strength was reduced significantly (P < 0.05) in all groups compared with control. The poloxamer+chitosan group had significantly (P < 0.05) reduced adhesion strength versus poloxamer only. There was a significant (P < 0.05) linear correlation (r = 0.931, P < 0.001) between adhesion grade and adhesion strength. We conclude that chitosan and the combination of poloxamer+chitosan were shown to effectively reduce adhesion area, grade, and strength.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты