MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1046/j.1365-2168.1999.01273.x

Медицинская библиотека · The British journal of surgery · 1999

24-h pH monitoring is necessary to assess acid reflux suppression in patients with Barrett's oesophagus undergoing treatment with proton pump inhibitors.

Ortiz A, Martínez de Haro L F, Parrilla P, Molina J, Bermejo J, Munitiz V

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Control of acid reflux is the main objective of treatment for Barrett's oesophagus. However, as these patients have a reduced sensitivity to acid reflux, disappearance of symptoms may not correlate with efficient control of acid reflux. The aim of this study was to determine in a group of patients with Barrett's oesophagus whether treatment with proton pump inhibitors suppressed pathological acid reflux once the symptoms of reflux had been controlled and the associated inflammatory lesions cured.

METHODS

Eighteen consecutive patients with Barrett's oesophagus were studied, all of whom presented with heartburn. Twenty-four-hour oesophageal pH monitoring before treatment showed pathological acid reflux in all cases: median percentage of total time with pH less than 4, 22 (range 8-52) per cent. All patients received proton pump inhibitors (dose 20-60 mg/day) until symptoms were controlled.

RESULTS

While on therapy, pH was reduced (median percentage of total time with pH less than 4, 3 versus 22 per cent; P < 0.001). However, three patients had persistent pathological rates of acid reflux.

CONCLUSION

Disappearance of symptoms is not a good indicator of control of pathological acid reflux in patients with Barrett's oesophagus. Twenty-four-hour pH monitoring should be performed for proper adjustment of the dose of medication.

Для цитирования: Ortiz A, Martínez de Haro L F, Parrilla P, Molina J, Bermejo J, Munitiz V. 24-h pH monitoring is necessary to assess acid reflux suppression in patients with Barrett's oesophagus undergoing treatment with proton pump inhibitors.. The British journal of surgery. 1999. DOI: 10.1046/j.1365-2168.1999.01273.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.