Медицинская библиотека · Journal of neonatal-perinatal medicine · 2019

Amplitude-integrated EEG in infants with neonatal abstinence syndrome.

Rana Divya, Pollard Leann, Rowland Jonathan, Dhanireddy Ramasubbareddy, Pourcyrous Massroor

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

BACKGROUND

To describe amplitude-integrated encephalogram (aEEG) characteristics of neonates with neonatal abstinence syndrome (NAS).

METHODS

This is a prospective observational study. Newborns exposed to prenatal opioids and their gestational matched controls were included. A single-channel aEEG was obtained using Olympic 6000 CFM monitor. The background activity (continuous/discontinuous), the amplitudes (μV) and the presence of sleep-wake cycle (SWC) were documented.

RESULTS

A total of 59 infants, 23 with NAS and 36 controls were enrolled. All aEEG were completed within 48 hours of life prior to initiation of treatment. Birth weight and gestational age were similar in both groups. An aEEG was abnormal (discontinuous pattern and/or absent SWC) in 78 % (18/23) of infants with NAS versus only 25% in control group (9/36), [OR 10.8, CI (2.7-46.5) P < 0.001]. 61% of infants with NAS had discontinuous pattern [OR 7.8, CI (2-32) P = 0.001] and 39% had absence of sleep-wake cycle [OR 7.1, CI (1.4-39.4) P = 0.007].

CONCLUSIONS

A majority of infants with NAS have abnormal aEEG activity.

Для цитирования: Rana Divya, Pollard Leann, Rowland Jonathan, Dhanireddy Ramasubbareddy, Pourcyrous Massroor. Amplitude-integrated EEG in infants with neonatal abstinence syndrome.. Journal of neonatal-perinatal medicine. 2019. DOI: 10.3233/npm-1834.