MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4293/jsls.2019.00037

Медицинская библиотека · JSLS : Journal of the Society of Laparoendoscopic Surgeons · 2019

Chemicals in Surgical Smoke and the Efficiency of Built-in-Filter Ports.

Ha Hyeong In, Choi Min Chul, Jung Sang Geun, Joo Won Duk, Lee Chan, Song Seung Hun, Park Hyun

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND

OBJECTIVES

Surgical smoke contains various malodorous and hazardous combustion byproducts. We aimed to analyze hydrocarbons accumulated in the abdominal cavity during laparoscopic gynecologic surgery and determine the efficiency of a built-in-filter port.

METHODS

We prospectively followed seven patients with benign uterine pathology. Surgical smoke was generated using laparoscopic or robotic electrocautery. The smoke was collected twice for each patient using a built-in-filter port and a conventional port. The concentrations of volatile organic compounds and aldehydes were determined using gas chromatography with mass spectrometry and high-performance liquid chromatography with ultraviolet visible light detection and compared using the paired-sample Wilcoxon signed-rank test.

RESULTS

Five volatile organic compounds and five aldehydes had toxic effects or unpleasant odors. The median concentration of formaldehyde before filtration (0.870 ppm) exceeded the time-weighted average concentration (0.75 ppm) of the Occupational Safety and Health Administration. Built-in-filter ports significantly reduced the concentration of five volatile organic compounds and two aldehydes but not that of formaldehyde, acetaldehyde, and propionaldehyde. Formaldehyde concentration decreased by 50% after filtration but remained above the recommended exposure limit (0.016 ppm) of the National Institute of Occupational Safety and Health.

CONCLUSIONS

Surgical smoke in minimally invasive gynecologic procedures contains several hazardous hydrocarbons including formaldehyde. Built-in-filter ports have the potential to reduce the exposure of surgical smoke to surgeons and operating room personnel; nevertheless, development of built-in-filter ports is necessary to improve the filtering efficiency for highly concentrated formaldehydes.

Для цитирования: Ha Hyeong In, Choi Min Chul, Jung Sang Geun, Joo Won Duk, Lee Chan, Song Seung Hun, Park Hyun. Chemicals in Surgical Smoke and the Efficiency of Built-in-Filter Ports.. JSLS : Journal of the Society of Laparoendoscopic Surgeons. 2019. DOI: 10.4293/jsls.2019.00037.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.