BACKGROUND

Although chronic renal insufficiency (CRI) is associated with increased cardiac and noncardiac mortality, there is limited data on the relationship between CRI and survival in patients with implantable cardioverter-defibrillators (ICDs), particularly across a wide range of renal function.

METHODS

We studied 507 consecutive patients receiving first-time ICDs from 1993-2003 at a single center. Preimplant serum creatinine measurements were used to determine glomerular filtration rate (GFR) and stage of chronic kidney disease (CKD). The primary outcome was time to death.

RESULTS

During a mean follow-up of 4 years, all-cause mortality through completion of follow-up increased stepwise by GFR stage (I: 16%, II: 20%, III: 35%; IV: 40%; V: 50%; P < 0.001 for trend). After multivariate adjustment, CRI was independently associated with death (HR = 1.7, P = 0.02), as were a serum creatinine >or=2.0 mg/dL (HR 2.5, P = 0.003) and the presence of end-stage renal disease (HR 6.8; P < 0.001). For every 10-unit decrease in GFR, the adjusted hazard of death increased 12% (P = 0.04).

CONCLUSION

The presence of CRI prior to implant is independently associated with increased mortality in patients receiving ICDs. The risk is proportional to the degree of renal dysfunction and is apparent even when GFR is only mildly reduced. Differences in mortality are observed within the first year of implant, and patients on dialysis are at highest risk. Because randomized trials of ICDs have not included large numbers of patients with moderate or severe renal disease, our findings may have important implications in prognosis and case selection of patients who otherwise meet current indications for ICD implantation.

Для цитирования: Turakhia Mintu P, Varosy Paul D, Lee Keane, Tseng Zian H, Lee Randall, Badhwar Nitish, Scheinman Melvin, Lee Byron K, Olgin Jeffrey E. Impact of renal function on survival in patients with implantable cardioverter-defibrillators.. Pacing and clinical electrophysiology : PACE. 2007. DOI: 10.1111/j.1540-8159.2007.00678.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.