MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.athoracsur.2003.12.058

Медицинская библиотека · The Annals of thoracic surgery · 2004

Late incidence and determinants of stroke after aortic and mitral valve replacement.

Ruel Marc, Masters Roy G, Rubens Fraser D, Bédard Pierre J, Pipe Andrew L, Goldstein William G, Hendry Paul J, Mesana Thierry G

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Stroke is a devastating complication in patients with prosthetic valves, but characterization of its late occurrence from a large cohort is lacking.

METHODS

Three thousand one hundred eighty-nine adult patients who underwent a total of 3,576 operations for left-heart valve replacement were managed with contemporary anticoagulation guidelines and prospectively followed in a dedicated clinic. Total follow-up was 20,096 patient years. Bootstrapped survival analysis was used to determine the impact of patient and valve related factors on the incidence of stroke.

RESULTS

Most strokes were embolic. Linearized embolic stroke rates were 1.3% +/- 0.2% per year for aortic bioprostheses, 1.4% +/- 0.2% per year for aortic mechanical valves, 1.3% +/- 0.3% per year for mitral bioprostheses, and 2.3% +/- 0.4% per year for mitral mechanical valves (p = 0.002, vs other implant types). Age more than 75 years, female gender, and smoking were independent risk factors after aortic and mitral valve replacement. Atrial fibrillation, coronary disease, and tilting-disc mechanical prostheses were independent predictors of embolic stroke after aortic valve replacement. Preoperative left ventricular (LV) dysfunction was an independent risk factor in patients with mitral prostheses. Primary operative indication, diabetes, redo status, or the presence of two prosthetic valves were not associated with an increased hazard. The addition of acetyl salicylic or dipyridamole to warfarin anticoagulation did not significantly lower embolic stroke risk in patients with mechanical prostheses.

CONCLUSIONS

Approximately 20% of patients with valve prostheses have an embolic stroke by 15 years after valve replacement. Some risk factors such as the avoidance of smoking, mitral mechanical prostheses, aortic tilting-disc valves, and proceeding to mitral surgery before LV dysfunction occurs are potentially modifiable.

Для цитирования: Ruel Marc, Masters Roy G, Rubens Fraser D, Bédard Pierre J, Pipe Andrew L, Goldstein William G, Hendry Paul J, Mesana Thierry G. Late incidence and determinants of stroke after aortic and mitral valve replacement.. The Annals of thoracic surgery. 2004. DOI: 10.1016/j.athoracsur.2003.12.058.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.