Augmentation index in the assessment of wave reflections and systolic loading.

Kaya Mehmet, Balasubramanian Vignesh, K-J Li John

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Augmentation index (AIx) is used to quantify the augmented systolic aortic pressure that impedes ventricular ejection. Its use as an index of wave reflections is questionable. We hypothesize that AIx is quantitatively different from the reflection coefficient under varied physiological conditions.

METHODS

42 datasets of aortic pressure and flow waveforms were obtained during induced hypertension (methoxamine infusion) and vasodilation (nitroprusside infusion) in our mongrel dog experiments (n = 5) and from Mendeley data during various interventions (vasoconstrictors, vasodilators, pacing, stimulation, hemorrhage and hemodilution). Wave reflections and principal components of reflection coefficients were computed for comparison to AIx and heart rate normalized AIx.

RESULTS

Principal reflection coefficient, Γ1, increased in hypertension and decreased in vasodilation, hemorrhage and hemodilution. AIx followed the trend in many cases but was consistently lower than Γ1 in almost all the subjects. The Bland-Altman analysis also showed that both AIx and normalized AIx underestimated Γ1. The relationship between augmentation index and reflection coefficient was explained by a linear regression model (r2 = 0.23, p < 0.01) in which AIx followed directional changes in Γ1 and the normalization of AIx resulted in a linear model that explained less variation in the relationship between AIx and Γ1.

CONCLUSION

AIx is a reasonable clinical trend indicator, albeit not an accurate surrogate measure of the amount of wave reflections.

Для цитирования: Kaya Mehmet, Balasubramanian Vignesh, K-J Li John. Augmentation index in the assessment of wave reflections and systolic loading.. Computers in biology and medicine. 2019. DOI: 10.1016/j.compbiomed.2019.103418.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.