MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00216-003-1967-1

Медицинская библиотека · Analytical and bioanalytical chemistry · 2003

Determination of berberine by measuring the enhanced total internal reflected fluorescence at water/tetrachloromethane interface in the presence of sodium dodecyl benzene sulfonate.

Feng Ping, Huang Cheng Zhi, Li Yuan Fang

СтатьяПеревод в очереди

Аннотация

A highly sensitive method for determination of berberine is proposed based on the measurements of total internal reflected fluorescence (TIRF) at water/ tetrachloromethane (H(2)O/CCl(4)) interface. In the pH range of 2.6-5.7, the co-adsorption of the berberine with the anionic surfactants such as sodium dodecyl benzene sulfonate (SDBS), sodium dodecylsulfonate (SDS), and sodium lauryl sulfate (SLS) occurs at the H(2)O/CCl(4 )interface, resulting in greatly enhanced TIRF signal characterized by the emission at 526 nm when excited with a 351 nm light beam. The enhanced TIRF intensity is in proportion to the berberine concentration in the range 0.2-10.0x10(-7) mol L(-1). The limit of detection is 1.7x10(-9) mol L(-1) (3sigma). It was found that ions such as Ca(II), Cu(II), Fe(III), Cd(II), Mg(II), Zn(II), Pb(II), and Al(III) can be allowed larger than 1.0x10(-4) mol L(-1). Meanwhile, the organic compounds such as vitamin B, saccharine, and amino acid do not display any effect for the present TIRF method even if they are larger than 1.0x10(-2) mol L(-1)in high concentration levels (larger than 1.0x10(-5) mol L(-1)). The results of determination for synthetic samples were agreement with the desired values, and the ones for tablets were identical with those obtained according to the method of Chinese Pharmacopoeia.

Для цитирования: Feng Ping, Huang Cheng Zhi, Li Yuan Fang. Determination of berberine by measuring the enhanced total internal reflected fluorescence at water/tetrachloromethane interface in the presence of sodium dodecyl benzene sulfonate.. Analytical and bioanalytical chemistry. 2003. DOI: 10.1007/s00216-003-1967-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.