The choice of embedding media affects image quality, tissue R2* , and susceptibility behaviors in post-mortem brain MR microscopy at 7.0T.

Dusek Petr, Madai Vince Istvan, Huelnhagen Till, Bahn Erik, Matej Radoslav, Sobesky Jan, Niendorf Thoralf, Acosta-Cabronero Julio, Wuerfel Jens

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: The quality and precision of post-mortem MRI microscopy may vary depending on the embedding medium used. To investigate this, our study evaluated the impact of 5 widely used media on: (1) image quality, (2) contrast of high spatial resolution gradient-echo (T1 and T2* -weighted) MR images, (3) effective transverse relaxation rate (R2* ), and (4) quantitative susceptibility measurements (QSM) of post-mortem brain specimens.

METHODS

Five formaldehyde-fixed brain slices were scanned using 7.0T MRI in: (1) formaldehyde solution (formalin), (2) phosphate-buffered saline (PBS), (3) deuterium oxide (D2 O), (4) perfluoropolyether (Galden), and (5) agarose gel. SNR and contrast-to-noise ratii (SNR/CNR) were calculated for cortex/white matter (WM) and basal ganglia/WM regions. In addition, median R2* and QSM values were extracted from caudate nucleus, putamen, globus pallidus, WM, and cortical regions.

RESULTS

PBS, Galden, and agarose returned higher SNR/CNR compared to formalin and D2 O. Formalin fixation, and its use as embedding medium for scanning, increased tissue R2* . Imaging with agarose, D2 O, and Galden returned lower R2* values than PBS (and formalin). No major QSM offsets were observed, although spatial variance was increased (with respect to R2* behaviors) for formalin and agarose.

CONCLUSIONS

Embedding media affect gradient-echo image quality, R2* , and QSM in differing ways. In this study, PBS embedding was identified as the most stable experimental setup, although by a small margin. Agarose and Galden were preferred to formalin or D2 O embedding. Formalin significantly increased R2* causing noisier data and increased QSM variance.

Для цитирования: Dusek Petr, Madai Vince Istvan, Huelnhagen Till, Bahn Erik, Matej Radoslav, Sobesky Jan, Niendorf Thoralf, Acosta-Cabronero Julio, Wuerfel Jens. The choice of embedding media affects image quality, tissue R2* , and susceptibility behaviors in post-mortem brain MR microscopy at 7.0T.. Magnetic resonance in medicine. 2018. DOI: 10.1002/mrm.27595.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.