On-X aortic valve replacement patients treated with low-dose warfarin and low-dose aspirin.

Oo Aung Y, Loubani Mahmoud, Gerdisch Marc W, Zacharias Joseph, Tsang Geoffrey M, Perchinsky Michael J, Hagberg Robert Carl, Joseph Mark, Sathyamoorthy Mohanakrishnan

СтатьяНаблюдательное исследованиеМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

To assess if warfarin targeted to international normalized ratio (INR) 1.8 (range 1.5-2.0) is safe for all patients with an On-X aortic mechanical valve.

METHODS

This prospective, observational registry follows patients receiving warfarin targeted at an INR of 1.8 (range 1.5-2.0) plus daily aspirin (75-100 mg) after On-X aortic valve replacement. The primary end point is a composite of thromboembolism, valve thrombosis and major bleeding. Secondary end points include the individual rates of thromboembolism, valve thrombosis and major bleeding, as well as the composite in subgroups of home or clinic-monitored INR and risk categorization for thromboembolism. The control was the patient group randomized to standard-dose warfarin (INR 2.0-3.0) plus daily aspirin 81 mg from the PROACT trial.

RESULTS

A total of 510 patients were enroled at 23 centres in the UK, USA and Canada. Currently, the median follow-up duration is 3.4 years, and median achieved INR is 1.9. The primary composite end point rate in the low INR patients is 2.31% vs 5.39% (95% confidence interval 4.12-6.93%) per patient-year in the PROACT control group, constituting a 57% reduction. Results are consistent in subgroups of home or clinic-monitored, and high-risk patients, with reductions of 56%, 57% and 57%, respectively. Major and total bleeding are decreased by 85% and 73%, respectively, with similar rates of thromboembolic events. No valve thrombosis occurred.

CONCLUSIONS

Interim results suggest that warfarin targeted at an INR of 1.8 (range 1.5-2.0) plus aspirin is safe and effective in patients with an On-X aortic mechanical valve with or without home INR monitoring.

Для цитирования: Oo Aung Y, Loubani Mahmoud, Gerdisch Marc W, Zacharias Joseph, Tsang Geoffrey M, Perchinsky Michael J, Hagberg Robert Carl, Joseph Mark, Sathyamoorthy Mohanakrishnan. On-X aortic valve replacement patients treated with low-dose warfarin and low-dose aspirin.. European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery. 2024. DOI: 10.1093/ejcts/ezae117.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.