MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1056/evidoa2300067

Медицинская библиотека · NEJM evidence · 2023

Apixaban or Warfarin in Patients with an On-X Mechanical Aortic Valve.

Wang Tracy Y, Svensson Lars G, Wen Jun, Vekstein Andrew, Gerdisch Marc, Rao Vijay U, Moront Michael, Johnston Doug, Lopes Renato D, Chavez Alma, Ruel Marc, Blackstone Eugene H, Becker Richard C, Thourani Vinod, Puskas John, Al-Khalidi Hussein R, Cable David G, Elefteriades John A, Pochettino Alberto, Wolfe J Alan, Graeve Allen, Sultan Ibrahim, Sabe Ashraf A, Michelena Hector I, Alexander John H

Клиническое исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Vitamin K antagonists are the only oral anticoagulants approved to prevent valve thrombosis and valve-related thromboembolism in patients with mechanical heart valves. Whether patients with an On-X mechanical aortic valve can be safely anticoagulated with apixaban is unknown.

METHODS

Patients with an On-X aortic valve implanted at least 3 months before enrollment were randomly assigned to receive apixaban 5 mg twice daily or warfarin (target international normalized ratio 2.0 to 3.0). The primary efficacy end point was the composite of valve thrombosis or valve-related thromboembolism with coprimary analyses comparing apixaban with warfarin for noninferiority and comparing the apixaban event rate with an objective performance criterion (OPC).

RESULTS

The trial was stopped after 863 participants were enrolled owing to an excess of thromboembolic events in the apixaban group. Most (94%) participants took aspirin. A total of 26 primary end-point events occurred, 20 (in 16 participants) in the apixaban group (4.2%/patient-year; 95% confidence interval [CI], 2.3 to 6.0) and 6 (in 6 participants) in the warfarin group (1.3%/patient-year; 95% CI, 0.3 to 2.3). The difference in primary end-point rates between the apixaban and warfarin groups was 2.9 (95% CI, 0.8 to 5.0); noninferiority and OPC success criteria were not met. Major bleeding rates were 3.6%/patient-year with apixaban and 4.5%/patient-year with warfarin.

CONCLUSIONS

Apixaban did not demonstrate noninferiority to warfarin and is less effective than warfarin for the prevention of valve thrombosis or thromboembolism in patients with an On-X mechanical aortic valve. (Funded by Artivion; ClinicalTrials.gov number, NCT04142658.)

Для цитирования: Wang Tracy Y, Svensson Lars G, Wen Jun, Vekstein Andrew, Gerdisch Marc, Rao Vijay U, Moront Michael, Johnston Doug, Lopes Renato D, Chavez Alma, Ruel Marc, Blackstone Eugene H, Becker Richard C, Thourani Vinod, Puskas John, Al-Khalidi Hussein R, Cable David G, Elefteriades John A, Pochettino Alberto, Wolfe J Alan, Graeve Allen, Sultan Ibrahim, Sabe Ashraf A, Michelena Hector I, Alexander John H. Apixaban or Warfarin in Patients with an On-X Mechanical Aortic Valve.. NEJM evidence. 2023. DOI: 10.1056/evidoa2300067.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.