MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0929-693x(01)00689-3

Медицинская библиотека · Archives de pediatrie : organe officiel de la Societe francaise de pediatrie · 2002

[Power Doppler sonography and acute pyelonephritis in children: comparison with Tc-DMSA scintigraphy].

el Hajjar M, Launay S, Hossein-Foucher C, Foulard M, Robert Y

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

UNLABELLED: Acute pyelonephritis is a common infection in children. The clinical and biological diagnosis is still sometimes difficult. For most authors, Technecium 99m dimercaptosuccinic acid scintigraphy is considered as the gold standard tool for diagnosis but it is invasive and expensive. The aim of our study was to compare the sensitivity and the specificity of B-mode sonography and power doppler to DMSA-Tc scintigraphy in acute pyelonephritis.

PATIENTS AND

METHODS

Forty-nine children were enrolled in this study with suspicion of pyelonephritis. All infants underwent doppler sonography and scintigraphy within 48 hours after their hospitalization. Doppler sonography criteria were increased kidney size, thickness of sinus wall, vascular defect, and various echogenicity of the kidneys (focal or diffuse hyperechogenicity or focal hypoechogenicity).

RESULTS

Among 28 children with a positive scintigraphy, 15 had a positive doppler sonography (sensitivity 54%) and 13 had a negative doppler sonography. Among 21 children with a negative scintigraphy, 20 had a negative doppler sonography (specificity 95%) and one had a positive doppler sonography.

CONCLUSION

In clinically suspected acute pyelonephritis, doppler sonography has a high specificity. A positive doppler sonography should avoid the use of scintigraphy.

Для цитирования: el Hajjar M, Launay S, Hossein-Foucher C, Foulard M, Robert Y. [Power Doppler sonography and acute pyelonephritis in children: comparison with Tc-DMSA scintigraphy].. Archives de pediatrie : organe officiel de la Societe francaise de pediatrie. 2002. DOI: 10.1016/s0929-693x(01)00689-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.