MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7754/clin.lab.2018.180420

Медицинская библиотека · Clinical laboratory · 2018

Evaluation of a Novel Immunochromatographic Assay for Detection of Human Adenoviruses from Throat Swab Samples Compared with Real-time PCR.

Ishiguro Nobuhisa, Kaiho Miki, Kikuta Hideaki, Togashi Takehiro, Sato Daisuke, Yasoshima Kohichi, Akutsu Yasushi, Yamanaka Tatsuru, Nagano Naoko, Ishizaka Akihito, Okamura Akiko, Kumita Yoshihiro, Nagano Hideki, Okano Motohiko, Ariga Tadashi

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

The aim of this study was to determine the sensitivity and specificity of a novel immunochromatographic assay (ICA) kit, ALSONIC® Adeno (Alfresa Pharma Co., Osaka, Japan), for the detection of human adenovirus (HAdV) from throat swab samples based on the results of real-time PCR. The incubation time required for the novel assay kit (5 minutes) is shorter than that required for other ICA kits that are available in Japan.

METHODS

Throat swab samples were taken from 151 patients aged 6 months to 15 years who were suspected of having respiratory tract infections caused by HAdV.

RESULTS

The sensitivity and specificity of the ICA for detection of HAdV were 92.2% (83/90) and 95.1% (58/61), respectively, and the assay showed positive and negative predictive values of 96.5% (83/86) and 89.2% (58/65), respectively.

CONCLUSIONS

ALSONIC® Adeno is suitable as a diagnostic tool in the acute phase of HAdV infection.

Для цитирования: Ishiguro Nobuhisa, Kaiho Miki, Kikuta Hideaki, Togashi Takehiro, Sato Daisuke, Yasoshima Kohichi, Akutsu Yasushi, Yamanaka Tatsuru, Nagano Naoko, Ishizaka Akihito, Okamura Akiko, Kumita Yoshihiro, Nagano Hideki, Okano Motohiko, Ariga Tadashi. Evaluation of a Novel Immunochromatographic Assay for Detection of Human Adenoviruses from Throat Swab Samples Compared with Real-time PCR.. Clinical laboratory. 2018. DOI: 10.7754/clin.lab.2018.180420.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.