MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.chroma.2012.11.066

Медицинская библиотека · Journal of chromatography. A · 2012

Miniaturized selective pressurized liquid extraction of polychlorinated biphenyls and polybrominated diphenyl ethers from feedstuffs.

Pena-Abaurrea M, Ramos J J, Gonzalez M J, Ramos L

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

A new miniaturized pressurized liquid extraction (PLE) with in-cell purification method has been developed for the simultaneous extraction of endogenous prioritary and toxic polychlorinated biphenyls (PCBs) and environmentally relevant tri- to deca-brominated diphenyl ether (PBDE) congeners from different feed matrices. Parameters affecting the efficiency of the selective PLE process, such as sorbent:matrix ratio, volume and nature of the extraction solvent, PLE working mode, extraction time and temperature, and amount of co-sorbents, were optimized. n-Hexane and n-hexane:dichloromethane (1:1, v/v) were used as extraction solvents. 8-mL of organic solvents and 3.5 g of sorbents sufficed for complete sample treatment. Only 0.25 g of feed sample were required for accurate determination of the endogenous PCBs studied using gas chromatography with a micro-electron capture detector (GC-μECD) during method development, and for PBDE analysis using either GC-μECD or gas chromatography with negative chemical ionization-quadrupole mass spectrometry (GC-NCI-qMS). Gas chromatography coupled to ion trap detection working in tandem mode, GC-ITD (MS/MS), was used for final PCB confirmation. Additional purification of the sample extracts was not required. The performance of the complete PLE-based method was evaluated at two spiking levels, 0.4 and 4 ng/g wet weight. Recoveries in the range 60-120% were obtained for PCBs, while those of PBDEs ranged from 86% to 114% for most of the target analytes. The relative standard deviations were in general lower than 20%. The optimized procedure was applied to the determination of the investigated PCBs and PBDEs in a variety of feed samples.

Для цитирования: Pena-Abaurrea M, Ramos J J, Gonzalez M J, Ramos L. Miniaturized selective pressurized liquid extraction of polychlorinated biphenyls and polybrominated diphenyl ethers from feedstuffs.. Journal of chromatography. A. 2012. DOI: 10.1016/j.chroma.2012.11.066.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.