MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acs.analchem.9b00636

Медицинская библиотека · Analytical chemistry · 2019

Reactivity Modulation of Benzopyran-Coumarin Platform by Introducing Electron-Withdrawing Groups: Specific Detection of Biothiols and Peroxynitrite.

Li Yong, Zhao Zhiwen, Xiao Yongsheng, Wang Xu, Jiao Xiaoyun, Xie Xilei, Zhang Jian, Tang Bo

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

A variety of fluorophores have been designed and created to fabricate organic fluorescent probes. Among these fluorophores, benzopyran-coumarin (BC) based fluorescent platform has attracted increasing attention as it shows multiple appropriate fluorescent and imaging capacities. Nevertheless, the analytical potential of BC is still urgently needed to be further excavated as its detection performance is hindered by the inherent drawbacks of current BC skeleton, that is, limited number of reactive sites. As such, in this work, by simply introducing electron-withdrawing (EW) substituent groups, we reconstructed BC skeleton to afford two fluorescent probes, BCB (-Br substitued) and BCN (-NO2 substitued), both of which featured two highly reactive sites. These two probes were capable of detecting peroxynitrite (ONOO-) and biothiols (hydrogen sulfide, glutathione, cysteine, and homocysteine) through naked eye and UV-vis absorption analysis in buffer solution. In addition, BCB was able to specifically sense biothiols with fluorescent analysis while BCN, with - NO2 instead of -Br, displayed more prominent fluorescent specificity toward ONOO-. This work provided a new strategy for the reactivity regulation of fluorophore through EW group introduction, as well as an alternative approach and method for the construction of fluorescent probes for other important biological species.

Для цитирования: Li Yong, Zhao Zhiwen, Xiao Yongsheng, Wang Xu, Jiao Xiaoyun, Xie Xilei, Zhang Jian, Tang Bo. Reactivity Modulation of Benzopyran-Coumarin Platform by Introducing Electron-Withdrawing Groups: Specific Detection of Biothiols and Peroxynitrite.. Analytical chemistry. 2019. DOI: 10.1021/acs.analchem.9b00636.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.