MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/jcbfm.2011.108

Медицинская библиотека · Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism · 2011

Quantification of ligand PET studies using a reference region with a displaceable fraction: application to occupancy studies with [(11)C]-DASB as an example.

Turkheimer Federico E, Selvaraj Sudhakar, Hinz Rainer, Murthy Venkatesha, Bhagwagar Zubin, Grasby Paul, Howes Oliver, Rosso Lula, Bose Subrata K

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

This paper aims to build novel methodology for the use of a reference region with specific binding for the quantification of brain studies with radioligands and positron emission tomography (PET). In particular: (1) we introduce a definition of binding potential BP(D)=DVR-1 where DVR is the volume of distribution relative to a reference tissue that contains ligand in specifically bound form, (2) we validate a numerical methodology, rank-shaping regularization of exponential spectral analysis (RS-ESA), for the calculation of BP(D) that can cope with a reference region with specific bound ligand, (3) we demonstrate the use of RS-ESA for the accurate estimation of drug occupancies with the use of correction factors to account for the specific binding in the reference. [(11)C]-DASB with cerebellum as a reference was chosen as an example to validate the methodology. Two data sets were used; four normal subjects scanned after infusion of citalopram or placebo and further six test-retest data sets. In the drug occupancy study, the use of RS-ESA with cerebellar input plus corrections produced estimates of occupancy very close the ones obtained with plasma input. Test-retest results demonstrated a tight linear relationship between BP(D) calculated either with plasma or with a reference input and high reproducibility.

Для цитирования: Turkheimer Federico E, Selvaraj Sudhakar, Hinz Rainer, Murthy Venkatesha, Bhagwagar Zubin, Grasby Paul, Howes Oliver, Rosso Lula, Bose Subrata K. Quantification of ligand PET studies using a reference region with a displaceable fraction: application to occupancy studies with [(11)C]-DASB as an example.. Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism. 2011. DOI: 10.1038/jcbfm.2011.108.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.