MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1528-1167.2006.00373.x

Медицинская библиотека · Epilepsia · 2006

Identification of the epileptogenic tuber in patients with tuberous sclerosis: a comparison of high-resolution EEG and MEG.

Jansen Floor E, Huiskamp Geertjan, van Huffelen Alexander C, Bourez-Swart Mireille, Boere Elvira, Gebbink Tineke, Vincken Koen L, van Nieuwenhuizen Onno

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: We compared epileptiform activity recorded with EEG and magnetoencephalography (MEG) in 19 patients with tuberous sclerosis complex (TSC) and epilepsy.

METHODS

High-resolution (HR) EEG, HR-MEG, and 1.5-T MRI scans were performed. Epileptiform spikes were identified in EEG and MEG recordings offline by three observers. Spikes for which the interobserver agreement (spike consensus) was >0.40 were used for source localization with CURRYV 3.0 software. MUSIC analysis was performed. The distance between the source determined from EEG and MEG recordings and the border of the closest tuber was calculated and compared.

RESULTS

Consensus spikes (kappa >0.4) were identified in 12 patients in the EEG recording and in 14 patients in the MEG recording. MEG sources were closer to tubers in all but one patient. Three patients underwent epilepsy surgery, two of whom are seizure free after complete resection of the tuber.

CONCLUSIONS

In patients with TSC, epileptogenic sources identified on MEG are closer to the presumed epileptogenic tuber than are similar sources identified on EEG. Moreover, spike consensus is greater with MEG. Clear identification of the epileptogenic zone may offer opportunities for surgery in patients with TSC with intractable epilepsy.

Для цитирования: Jansen Floor E, Huiskamp Geertjan, van Huffelen Alexander C, Bourez-Swart Mireille, Boere Elvira, Gebbink Tineke, Vincken Koen L, van Nieuwenhuizen Onno. Identification of the epileptogenic tuber in patients with tuberous sclerosis: a comparison of high-resolution EEG and MEG.. Epilepsia. 2006. DOI: 10.1111/j.1528-1167.2006.00373.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.