m+Medelevator.RU
← Поиск публикаций
International journal of epidemiology · 2003

Acute effect of sulphur dioxide from a power plant on pulmonary function of children, Thailand.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Aekplakorn Wichai, Loomis Dana, Vichit-Vadakan Nuntavarn, Shy Carl, Wongtim Somkiat, Vitayanon Paipun

Аннотация

BACKGROUND: Epidemiological studies have shown reversible declines of lung function in response to air pollution, but research on the independent effect of short-term exposure to ambient sulphur dioxide (SO2) on pulmonary function is limited. This study evaluated the association of short-term exposure to increased ambient SO2 and daily pulmonary function changes among children with and without asthma.

METHODS: The associations of daily exposure to SO2 and particulate matter 10 microm in diameter (PM10) with pulmonary function were examined in 175 asthmatic and non-asthmatic children aged 6-14 years who resided near a coal-fired power plant in Thailand. Each child performed daily pulmonary function tests during the 61-day study period. General linear mixed models were used to estimate the association of air pollution and pulmonary function controlling for time, temperature, co-pollutants, and autocorrelation.

RESULTS: In the asthmatic children, a daily increase in SO2 was associated with negligible declines in pulmonary function, but a small negative association was found between PM10 and pulmonary function. A 10-microg/m(3) increment was associated with changes in the highest forced vital capacity (FVC) (-6.3 ml, 95% CI: -9.8, -2.8), forced expiratory volume at 1 second (FEV(1)) (-6.0 ml, 95% CI: -9.2, 2.7), peak expiratory flow rate (PEFR) (-18.9 ml.sec(-1), 95% CI: -28.5, -9.3) and forced expiratory flow 25 to 75% of the FVC (FEF(25-75%)) (-3.7 ml.sec(-1), 95% CI: -10.9, 3.5). No consistent associations between air pollution and pulmonary function were found for non-asthmatic children.

CONCLUSION: Declines in pulmonary function among asthmatic children were associated with increases in particulate air pollution, rather than with increases in SO2.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты