MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10877-018-0235-z

Медицинская библиотека · Journal of clinical monitoring and computing · 2018

Photoplethysmographic characterization of vascular tone mediated changes in arterial pressure: an observational study.

Tusman Gerardo, Acosta Cecilia M, Pulletz Sven, Böhm Stephan H, Scandurra Adriana, Arca Jorge Martinez, Madorno Matías, Sipmann Fernando Suarez

СтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

To determine whether a classification based on the contour of the photoplethysmography signal (PPGc) can detect changes in systolic arterial blood pressure (SAP) and vascular tone. Episodes of normotension (SAP 90-140 mmHg), hypertension (SAP > 140 mmHg) and hypotension (SAP < 90 mmHg) were analyzed in 15 cardiac surgery patients. SAP and two surrogates of the vascular tone, systemic vascular resistance (SVR) and vascular compliance (Cvasc = stroke volume/pulse pressure) were compared with PPGc. Changes in PPG amplitude (foot-to-peak distance) and dicrotic notch position were used to define 6 classes taking class III as a normal vascular tone with a notch placed between 20 and 50% of the PPG amplitude. Class I-to-II represented vasoconstriction with notch placed > 50% in a small PPG, while class IV-to-VI described vasodilation with a notch placed < 20% in a tall PPG wave. 190 datasets were analyzed including 61 episodes of hypertension [SAP = 159 (151-170) mmHg (median 1st-3rd quartiles)], 84 of normotension, SAP = 124 (113-131) mmHg and 45 of hypotension SAP = 85(80-87) mmHg. SAP were well correlated with SVR (r = 0.78, p < 0.0001) and Cvasc (r = 0.84, p < 0.0001). The PPG-based classification correlated well with SAP (r = - 0.90, p < 0.0001), SVR (r = - 0.72, p < 0.0001) and Cvasc (r = 0.82, p < 0.0001). The PPGc misclassified 7 out of the 190 episodes, presenting good accuracy (98.4% and 97.8%), sensitivity (100% and 94.9%) and specificity (97.9% and 99.2%) for detecting episodes of hypotension and hypertension, respectively. Changes in arterial pressure and vascular tone were closely related to the proposed classification based on PPG waveform.Clinical Trial Registration NTC02854852.

Для цитирования: Tusman Gerardo, Acosta Cecilia M, Pulletz Sven, Böhm Stephan H, Scandurra Adriana, Arca Jorge Martinez, Madorno Matías, Sipmann Fernando Suarez. Photoplethysmographic characterization of vascular tone mediated changes in arterial pressure: an observational study.. Journal of clinical monitoring and computing. 2018. DOI: 10.1007/s10877-018-0235-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.