Biochemical and biophysical research communications · 1999
Validation of lucigenin as a chemiluminescent probe to monitor vascular superoxide as well as basal vascular nitric oxide production.
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Skatchkov M P, Sperling D, Hink U, Mülsch A, Harrison D G, Sindermann I, Meinertz T, Münzel T
Аннотация
Lucigenin has been widely used as a chemiluminescent substrate to monitor vascular superoxide (O*-2) formation. The validity of lucigenin for detection of O*-2 has been questioned because O*-2 is generated by lucigenin itself. It has been shown that the concentration of lucigenin is a critical parameter affecting the validity of this assay. In the present studies we evaluated a reduced concentration of lucigenin (5 microM) as a tool to quantify O*-2 production in vascular tissue. Lucigenin-induced effects on endothelial function were assessed by isometric tension recording of isolated aortic rings suspended in organ baths. The effects of lucigenin on O*-2 production were studied using spin trapping and electron spin resonance spectroscopy. Lucigenin at 250 microM but not at 5 microM caused a significant attenuation of endothelium-dependent relaxations to acetylcholine, which was prevented by pretreatment with superoxide dismutase. Spin-trapping studies revealed that lucigenin at 250 microM increased vascular O*-2 production several fold while 5 microM lucigenin did not stimulate O*-2 production. Inhibition of NO synthase by NG-momomethyl-l-arginine as well as the removal of the endothelium almost doubled lucigenin-derived chemiluminescence (LDCL), indicating that basal production of endothelium-derived NO depresses the baseline chemiluminescence signal. Thus, lucigenin at a concentration of 5 microM seems to be a sensitive and valid probe for assessing O*-2 in vascular tissue. It can also be used as an indirect probe to estimate basal vascular NO release.
Предметные рубрики MeSH
AcetylcholineAcridinesAnimalsAortaElectron Spin Resonance SpectroscopyEndothelium, VascularHypercholesterolemiaIn Vitro TechniquesLuminescent MeasurementsMuscle, Smooth, VascularNitric OxidePentetic AcidRabbitsReproducibility of ResultsScintillation CountingSuperoxide DismutaseSuperoxidesVasodilationomega-N-Methylarginine