Медицинская библиотека · Clinical chemistry · 2001

Homogeneous enzyme immunoassay for triiodothyronine in serum.

Karapitta C D, Sotiroudis T G, Papadimitriou A, Xenakis A

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

The concentration of triiodothyronine (T3) in human serum is extremely low and can be determined only by very sensitive methods. We developed a homogeneous enzyme immunoassay for T3 analysis in unextracted serum.

METHODS

A T(3) derivative was conjugated to the -SH groups of glycogen phosphorylase b (GPb) from rabbit muscle. Conjugation caused inhibition of enzyme activity, and the enzyme conjugate was reactivated upon binding of anti-T3 antibody. Activation was blocked by the presence of non-antibody-bound T3; this was the basis for the development of the homogeneous enzyme immunoassay for T3 by determining GPb activity fluorometrically.

RESULTS

We used furosemide to block the interaction of T3 with serum proteins with T3-binding sites, avoiding any serum treatment step. T3 was measured in the range 0.3-8 microg/L. T3 values obtained by this assay correlated well with those obtained by a RIA (y = 0.97x - 0.07 microg/L; r = 0.96; n = 92). Within- and between-run imprecision (CV) was 5-9% for normal and high concentrations and 16-20% for low concentrations.

CONCLUSIONS

Chemical modification of GPb with a T3 derivative allows the development of a simple homogeneous enzyme immunoassay for T3 in unextracted serum.

Для цитирования: Karapitta C D, Sotiroudis T G, Papadimitriou A, Xenakis A. Homogeneous enzyme immunoassay for triiodothyronine in serum.. Clinical chemistry. 2001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.