Arthroscopic meniscal repair with an all-inside suture system.
Аннотация
OBJECTIVE
Application of an arthroscopic suture system to restore the form and function of the meniscus by adaptation of a longitudinal tear close to the base.
INDICATIONS: Unstable longitudinal tears near the base of the meniscus, mainly in the posterior horn of the medial or lateral of the meniscus. Dislocated bucket-handle tears of the medial and lateral meniscus close to the base.
CONTRAINDICATIONS: Poor tissue quality with fibrillated meniscal tissue. Meniscal tears in the avascular zone (zone I). Insufficient blood supply from the joint capsule and the base of the meniscus. Degenerative meniscal lesions. Anterior or posterior knee joint instability. Allergic reactions to nonresorbable suture material.
SURGICAL TECHNIQUE: Standard anterior arthroscopic portals. Arthroscopic assessment of the meniscal tear using the probe. Revitalization of the tear margins and perforation of the meniscal base to induce bleeding. Adaptation of the tear margins and fixation with a suture-anchor system using an ipsilateral standard portal for tears in the posterior horn or by way of a contralateral standard portal for tears in the lateral horn.
POSTOPERATIVE MANAGEMENT: Full weight bearing with the knee in extension in a knee immobilizer, relative to the pain threshold in the 1st postoperative week. Range of motion exercises without weight bearing from full extension to 90 degrees knee flexion (0/0/90). If simultaneous reconstruction of the anterior cruciate ligament (ACL) is being performed, rehabilitation protocols follow the principles for ACL reconstruction.
RESULTS
Since the year 2000, meniscal tears in more than 300 patients have been repaired with the all-inside suture system. In the context of a multicenter study by ESSKA (European Society for Sports Medicine, Surgery and Arthroscopy) involving 20 patients, the result was evaluated by direct MRI arthrography (gadolinium). The suture bar anchors were generally not detectable, the incision channels produced a hypodense signal in the meniscus tissue. If re-rupture occurred, it was because the meniscus had pulled out of the suture loop. Cartilaginous lesions were not found. There were no complications related to the nonresorbable suture bar anchors.