MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1001/archneur.60.11.1580

Медицинская библиотека · Archives of neurology · 2003

Diffusion-weighted magnetic resonance imaging and identification of the epileptogenic tuber in patients with tuberous sclerosis.

Jansen Floor E, Braun Kees P J, van Nieuwenhuizen Onno, Huiskamp Geertjan, Vincken Koen L, van Huffelen Alexander C, van der Grond Jeroen

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Patients with tuberous sclerosis complex and drug-resistant epilepsy may be considered candidates for epilepsy surgery. This demands the unambiguous demonstration of the epileptogenicity of one of the tubers.

OBJECTIVE

To test whether diffusion-weighted magnetic resonance imaging enables differentiation of epileptogenic tubers from inert ones.

METHODS

In 4 patients with clear unifocal interictal spike activity, fluid-attenuated inversion recovery and diffusion-weighted magnetic resonance imaging were performed. Apparent diffusion coefficient maps were calculated in the identified epileptogenic tuber and compared withthose in nonepileptogenic tubers and regions of normal-appearing cortex.

RESULTS

A significant increase in the apparent diffusion coefficient was found in the epileptogenic tubers. Furthermore, the apparent diffusion coefficient of the nonepileptogenic tubers was significantly higher than the trace apparent diffusion coefficient of regions of normal-appearing cortex.

CONCLUSION

Diffusion-weighted magnetic resonance imaging may be of clinical importance for the identification of epileptogenic tubers in patients with tuberous sclerosis and intractable epilepsy.

Для цитирования: Jansen Floor E, Braun Kees P J, van Nieuwenhuizen Onno, Huiskamp Geertjan, Vincken Koen L, van Huffelen Alexander C, van der Grond Jeroen. Diffusion-weighted magnetic resonance imaging and identification of the epileptogenic tuber in patients with tuberous sclerosis.. Archives of neurology. 2003. DOI: 10.1001/archneur.60.11.1580.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.