MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5603/cj.a2018.0077

Медицинская библиотека · Cardiology journal · 2018

The comparison of endothelial function between conduit artery and microvasculature in patients with coronary artery disease.

Tajima Emi, Sakuma Masashi, Tokoi Seiko, Matsumoto Hisae, Saito Fumiya, Watanabe Ryo, Toyoda Shigeru, Abe Shichiro, Inoue Teruo

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Flow-mediated dilation (FMD) and reactive hyperemia-peripheral arterial tonometry (RH-PAT) are both established modalities to assess vascular endothelial function. However, clinical significance of FMD and RH-PAT may be different because these methods measure vascular function in different vessels (conduit arteries and resistance vessels).

METHODS

To elucidate differences in the clinical significance of FMD and RH-PAT, a simultaneous determination of FMD was performed and reactive hyperemia index (RHI) measured by RH-PAT in 131 consecutive patients who underwent coronary angiography for suspicion of coronary artery disease (CAD).

RESULTS

There was no significant correlation between FMD and RHI in patients overall. When patients were divided into four groups: FMD ≥ 6%/RHI ≥ 1.67 group, FMD ≥ 6%/RHI < 1.67 group, FMD < 6%/RHI ≥ 1.67 group and FMD < 6%/RHI < 1.67 group, the highest incidence of multivessel CAD was seen in the FMD < 6%/RHI < 1.67 group (52%). Multiple logistic regression analysis showed that a prevalence of both FMD < 6% and RHI < 1.67 was an independent predictor of multivessel CAD (odds ratio: 4.160, 95% confidence interval: 1.505-11.500, p = 0.006). RHI was negatively correlated with the baseline vessel diameter (R = -0.268, p = 0.0065) and maximum vessel diameter (R = -0.266, p = 0.0069) in patients with FMD < 6%, whereas these correlations were absent in patients with FMD ≥ 6%.

CONCLUSIONS

Present results suggest that noninvasive assessment of vascular endothelial functions provide pathophysiological information on both conduit arteries and resistance vessels in patients with CAD.

Для цитирования: Tajima Emi, Sakuma Masashi, Tokoi Seiko, Matsumoto Hisae, Saito Fumiya, Watanabe Ryo, Toyoda Shigeru, Abe Shichiro, Inoue Teruo. The comparison of endothelial function between conduit artery and microvasculature in patients with coronary artery disease.. Cardiology journal. 2018. DOI: 10.5603/cj.a2018.0077.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.