DOI 10.1097/mca.0000000000000423
Efficacy and safety of intracoronary verapamil versus sodium nitroprusside for the prevention of microvascular obstruction during primary percutaneous coronary intervention for ST-segment elevation myocardial infarction.
Аннотация
OBJECTIVE
The aim of this study was to compare the role of intracoronary (IC) verapamil versus sodium nitroprusside (SNP) in the prevention of microvascular obstruction (MVO) during a primary percutaneous coronary intervention (pPCI).
BACKGROUND
A head-to-head comparison between verapamil and SNP in the prevention of MVO lacks evidence.
PATIENTS AND
METHODS
Sixty patients with ST-segment elevation myocardial infarction were randomized to receive IC verapamil (n=30) versus SNP (n=30) during pPCI. The primary outcome was the incidence of angiographic MVO as defined by Thrombolysis In Myocardial Infarction flow less than 3 or Thrombolysis In Myocardial Infarction flow 3 with myocardial blush grade less than 2. The secondary outcomes were the percentage of ST-segment resolution on 12-lead ECG, left ventricular ejection fraction and wall motion score index by two-dimensional echocardiography at 3-5 days after pPCI, as well as major adverse cardiovascular events at 30 days. Safety outcomes were the incidence of hypotension and/or bradycardia during pPCI.
RESULTS
Verapamil was associated with lower incidence of angiographic MVO compared with SNP (13.3 vs. 40%, respectively; P=0.02), as well as superior ST-segment resolution greater than or equal to 70% (33.3 vs. 6.7%, respectively; P=0.01). There was a trend towards improved left ventricular ejection fraction with verapamil (42.6±4.9 vs. 40.4±4.7%, respectively; P=0.09), but with similar wall motion score index (1.43±0.1 vs. 1.45±0.2, respectively; P=0.14). Both groups had similar 30-day major adverse cardiovascular events (3.3 vs. 6.7%, respectively; P=0.55). Verapamil was associated with lower incidence of hypotension compared with SNP (3.3 vs. 20%, respectively; P=0.04).
CONCLUSION
In pPCI, IC verapamil results in significant improvements in MVO with a better safety profile compared with SNP. Larger trials should be conducted to confirm these results.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.