DOI 10.1111/j.1469-7610.2004.00313.x
The reliability and validity of tasks measuring perception of rapid sequences in children with dyslexia.
Аннотация
BACKGROUND
Claims that children with reading and oral language deficits have impaired perception of sequential sounds are usually based on psychophysical measures of auditory temporal processing (ATP) designed to characterise group performance. If we are to use these measures (e.g., the Tallal, 1980, Repetition Test) as the basis for intervention in language and literacy deficits, we need to demonstrate that they can effectively quantify individual differences. Therefore, questions of standardisation, reliability and construct validity can no longer be ignored.
METHOD: We explored these issues in three studies: (i) 52 Dyslexics and Good Readers aged 8 to 11 years performed a task requiring perception of rapid sequences (PRS) based on the Tallal Repetition Test; (ii) a subgroup of the initial sample was retested on the task three to four months later, and after extended practice; (iii) a further subgroup then completed a rate of auditory processing task using a backward recognition masking paradigm.
RESULTS
With a standardised methodology, we were able to replicate previous results with the PRS task, and demonstrate moderate reliability of measurement across time and practice. However, there were large effects of exposure and practice, and the task did not seem useful for identifying absolute and continuing deficits in given individuals.
CONCLUSIONS
Our results call into question the use of this type of task as an individual measure of ATP. Neither is it certain that it is capturing what is currently understood as ATP.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.