MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jtcvs.2016.05.051

Медицинская библиотека · The Journal of thoracic and cardiovascular surgery · 2016

Performance of allogeneic bioengineered replacement pulmonary valves in rapidly growing young lambs.

Quinn Rachael W, Bert Arthur A, Converse Gabriel L, Buse Eric E, Hilbert Stephen L, Drake William B, Hopkins Richard A

СтатьяКомментарийПеревод в очереди

Аннотация

BACKGROUND

Cardiac allometric organ growth after pediatric valve replacement can lead to patient-prosthesis size mismatch and valve re-replacement, which could be mitigated with allogeneic decellularized pulmonary valves treated with collagen conditioning solutions to enhance biological and mechanical performance, termed "bioengineered valves." In this study, we evaluated functional, dimensional, and biological responses of these bioengineered valves compared with traditional cryopreserved valves implanted in lambs during rapid somatic growth.

METHODS

From a consanguineous flock of 13 lambs, the pulmonary valves of 10 lambs (mean weight, 19.6 ± 1.4 kg) were replaced with 7 bioengineered valves or 3 classically cryopreserved valves. After 6 months, the 10 lambs with implanted valves and 3 untreated flock mates were compared by echocardiography, cardiac catheterization, and explant pathology.

RESULTS

Increases in body mass, valve geometric dimensions, and effective orifice areas were similar in the 2 groups of lambs. The bioengineered valves had higher median cusp-to-cusp coaptation areas (34.6%; interquartile range, 21.00%-35.13%) and were more similar to native valves (43.4%; interquartile range, 42.59%-44.01%) compared with cryopreserved valves (13.2%; interquartile range, 7.07%-13.91%) (P = .043). Cryopreserved valves cusps, but not bioengineered valve cusps, were thicker than native valve cusps (P = .01). Histologically, cryopreserved valves demonstrated less than native cellularity, whereas bioengineered valves that were acellular at the time of surgery gained surface endothelium and subsurface myofibroblast interstitial cells in pulmonary artery, sinus wall, and cusp base regions.

CONCLUSIONS

Biological valve conduits can enlarge via passive dilatation without matrix synthesis, but this would result in decreased cusp coaptational areas. Bioengineered valves demonstrated similar annulus enlargement as cryopreserved valves but usually retained larger areas of cuspal coaptation. Heat-shock protein 47-positive (collagen-synthesizing) cells were present in previously acellular bioengineered sinus walls and cusp bases, but rarely in more distal cusp matrices.

Для цитирования: Quinn Rachael W, Bert Arthur A, Converse Gabriel L, Buse Eric E, Hilbert Stephen L, Drake William B, Hopkins Richard A. Performance of allogeneic bioengineered replacement pulmonary valves in rapidly growing young lambs.. The Journal of thoracic and cardiovascular surgery. 2016. DOI: 10.1016/j.jtcvs.2016.05.051.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.